Measuring the content of hemoglobin in the blood and the percentage of saturation of hemoglobin (the oxygen saturation of the blood) is a simple process and is readily available to physicians. Using the fact that each gram of hemoglobin can carry 1.34 mL of O 2 , the oxygen content of the blood (either arterial or venous) can be estimated by ...
Modalities applied to measurement of ejection fraction is an emerging field of medical mathematics and subsequent computational applications. The first common measurement method is echocardiography, [7] [8] although cardiac magnetic resonance imaging (MRI), [8] [9] cardiac computed tomography, [8] [9] ventriculography and nuclear medicine (gated SPECT and radionuclide angiography) [8] [10 ...
Perfusion may also refer to fixation via perfusion, used in histological studies. Perfusion is measured as the rate at which blood is delivered to tissue, [2] or volume of blood per unit time (blood flow) per unit tissue mass. The SI unit is m 3 /(s·kg) [citation needed], although for human organs perfusion is typically reported in ml/min/g. [3]
For this reason, the blood flow velocity is the fastest in the middle of the vessel and slowest at the vessel wall. In most cases, the mean velocity is used. [18] There are many ways to measure blood flow velocity, like videocapillary microscoping with frame-to-frame analysis, or laser Doppler anemometry. [19]
The ophthalmic artery (OA), a unique vessel with intracranial and extracranial segments, is used as a pressure sensor and as a natural pair of scales for absolute ICP value in mmHg or mmH2O measurement. Blood flow in the intracranial OA segment is affected by intracranial pressure, while flow in the extracranial (intraorbital) OA segment is ...
Venous blood with an oxygen concentration of 15 mL/100 mL would therefore lead to typical values of the a-vO 2 diff at rest of around 5 mL/100 mL. During intense exercise, however, the a-vO 2 diff can increase to as much as 16 mL/100 mL due to the working muscles extracting far more oxygen from the blood than they do at rest. [citation needed]
A man undergoing whole body plethysmography. A modern body plethysmograph using ultrasound. A plethysmograph is an instrument for measuring changes in volume within an organ or whole body (usually resulting from fluctuations in the amount of blood or air it contains). The word is derived from the Greek "plethysmos" (increasing, enlarging ...
Standardized Kt/V, also std Kt/V, is a way of measuring dialysis adequacy. It was developed by Frank Gotch and is used in the United States to measure dialysis. Despite the name, it is quite different from Kt/V. In theory, both peritoneal dialysis and hemodialysis can be quantified with std Kt/V.