enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pensky–Martens closed-cup test - Wikipedia

    en.wikipedia.org/wiki/Pensky–Martens_closed-cup...

    This allows the development of an equilibrium between the liquid and the air volume. The ignition source is directed into the cup at regular intervals with simultaneous interruption of stirring. The test concludes upon observation of a flash that spreads throughout the inside of the cup. The corresponding temperature is the liquid's flash point.

  3. Fire test - Wikipedia

    en.wikipedia.org/wiki/Fire_test

    A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation. Successful tests in laboratories holding national accreditation for testing and certification result in the issuance of a certification listing .

  4. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...

  5. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    Balancing is the methodical regulation of system fluid flows (air or water) through the use of acceptable procedures to achieve the desired or specified design airflow or water flow. When beginning the balance of a system, you must locate the terminal with the least amount of flow in regards to the engineer's drawing.

  6. Cleveland open-cup method - Wikipedia

    en.wikipedia.org/wiki/Cleveland_open-cup_method

    The lowest temperature at which a small test flame passing over the surface of the liquid causes the vapor to ignite is considered the chemical's flash point. This apparatus may also be used to determine the chemical's fire point which is considered to have been reached when the application of the test flame produces at least five continuous ...

  7. Fire point - Wikipedia

    en.wikipedia.org/wiki/Ignition_point

    The fire point, or combustion point, of a fuel is the lowest temperature at which the liquid fuel will continue to burn for at least five seconds after ignition by an open flame of standard dimension. [1] At the flash point, a lower temperature, a substance will ignite briefly, but vapour might not be produced at a rate to sustain the fire ...

  8. Flashover - Wikipedia

    en.wikipedia.org/wiki/Flashover

    This is referred to as smoke explosion or fire gas ignition depending on the severity of the combustion process. A hot rich flashover occurs when the hot smoke with flammable gas ratio above the upper limit of flammability range and temperature higher than the ignition temperature leaves the compartment. Upon dilution with air it can ...

  9. Instrumentation in petrochemical industries - Wikipedia

    en.wikipedia.org/wiki/Instrumentation_in...

    The fire and gas detection system comprises local sensors to detect the presence of gas, smoke or fire. These initiate alarms in the control room. Simultaneous detection of multiple sensors initiates action to start firewater pumps and close fire dampers in enclosed spaces. The petrochemical plant may have several levels of shutdown.