Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.
The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps are normally high pressure units that take suction from a condensate return system and can be of the centrifugal pump type or positive displacement type.
If this vent valve has not be opened sufficiently, the deaerator will not work properly, resulting in feed water with a high oxygen content going to the boilers. Should the boiler not have an oxygen-content analyzer, a high level in the boiler chlorides may indicate the vent valve not being far enough open.
The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).
This kind of heater will normally require a feed pump at both the feed inlet and outlet since the pressure in the heater is between the boiler pressure and the condenser pressure. A deaerator is a special case of the open feedwater heater which is specifically designed to remove non-condensable gases from the feedwater.
The steam heats the water in the tank; The water in the tank serves as a surge volume within the steam plant. The deaerating feed tank's surge volume allows the ship to change "bells" (steam turbine power output) and change the ship's speed without running the feed pump dry or flooding the turbines with liquid water.
A sectional diagram of a typical steam boiler feed injector, simplified to show the major parts common to such injectors, showing typical proportions, and using colour and shading to hint at temperature, pressure, and velocity variations in the fluid flows. The SVG was hand coded using a text editor.
Water is introduced into the steam drum and is circulated around the boiler, leaving only as steam. What makes the forced circulation boiler different is its use of a secondary pump that circulates water through the boiler. The secondary pump takes the feed water going to the boiler and raises the pressure of the water going in.