Search results
Results from the WOW.Com Content Network
The continuous stirred-tank reactor (CSTR), also known as vat-or backmix reactor, mixed flow reactor (MFR), or a continuous-flow stirred-tank reactor (CFSTR), is a common model for a chemical reactor in chemical engineering and environmental engineering. A CSTR often refers to a model used to estimate the key unit operation variables when using ...
Custody transfer measurements involve measurements in pipelines, storage tanks, transportation tanks (tankers, trailers or railway tanks) - whole fuel distribution process must be traceable. In order measurements can be made in a volume or mass units (or both), so various metering methods are commonly used. [3]
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
In thermodynamics, the Volume Correction Factor (VCF), also known as Correction for the effect of Temperature on Liquid (CTL), is a standardized computed factor used to correct for the thermal expansion of fluids, primarily, liquid hydrocarbons at various temperatures and densities. [1]
Magnetic flux leakage (TFI or Transverse Field Inspection technology) is a magnetic method of nondestructive testing to detect corrosion and pitting in steel structures, for instance: pipelines and storage tanks. The basic principle is that the magnetic field "leaks" from the steel at areas where there is corrosion or missing metal.
The Symons pan or tank is a standard instrument of the UK Met Office. It is a steel container 1.83 m (6 ft) on a side and 0.61 m (2 ft) deep, sunk into the ground with an above-ground rim of 7.6–10 centimetres (3.0–3.9 in) and is painted black internally.
Calibration gases: Span gases are used for testing and calibrating gas detection equipment by exposing the sensor to a known concentration of a contaminant. The gases are used as a reference point to ensure correct readings after calibration and have very accurate composition, with a content of the gas to be detected close to the set value for ...