The COP of absorption chillers can be improved by adding a second or third stage. Double and triple effect chillers are significantly more efficient than single effect chillers, and can surpass a COP of 1. They require higher pressure and higher temperature steam, but this is still a relatively small 10 pounds of steam per hour per ton of cooling.
A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...
The water in the chilled water circuit will be lowered to the Wet-bulb temperature or dry-bulb temperature before proceeding to the water chiller, where it is cooled to between 3 and 6 °C and pumped to the air handler, where the cycle is repeated. [3] The equipment required includes chillers, cooling towers, pumps and electrical control ...
A water chiller [1] is a device used to lower the temperature of water. Most chillers use refrigerant in a closed loop system to facilitate heat exchange from water where the refrigerant is then pumped to a location where the waste heat is transferred to the atmosphere. However, there are other methods in performing this action.
Cooling capacity is the measure of a cooling system's ability to remove heat. [1] It is equivalent to the heat supplied to the evaporator/boiler part of the refrigeration cycle and may be called the "rate of refrigeration" or "refrigeration capacity".
In Fig.8 the pressures and temperatures refer to the case of a nitrogen liquefier. At the inlet of the compressor the gas is at room temperature (300 K) and a pressure of 1 bar (point a). The compression heat is removed by cooling water.
In a snow storage frozen water (snow and/or ice) is saved in some kind of storage (pile, pit, cavern etc.). The cold is utilized by pumping melt water to the cooling object, directly in a district cooling system or indirect by a heat exchanger. The lukewarm melt water is then pumped back to the snow where it gets cooled and mixed with new melt ...
In the United Kingdom, a Seasonal Energy Efficiency ratio (SEER) for refrigeration and air conditioning products, similar to the ESEER but with different load profile weighting factors, is used for part of the Building Regulations Part L calculations within the Simplified Building Energy Model (SBEM) software, and are used in the production of Energy Performance Certificates (EPC) for new ...