Since pacemaker correction of the third-degree block requires full-time pacing of the ventricles, a potential side effect is pacemaker syndrome, and may necessitate the use of a biventricular pacemaker, which has an additional 3rd lead placed in a vein in the left ventricle, providing more coordinated pacing of both ventricles.
In a 12-lead ECG, all leads except the limb leads are assumed to be unipolar (aVR, aVL, aVF, V 1, V 2, V 3, V 4, V 5, and V 6). The measurement of a voltage requires two contacts and so, electrically, the unipolar leads are measured from the common lead (negative) and the unipolar lead (positive).
The use of additional ECG leads like right-sided leads V3R and V4R and posterior leads V7, V8, and V9 may improve sensitivity for right ventricular and posterior myocardial infarction. In spite of these limitations, the 12 lead ECG stands at the center of risk stratification for the patient with suspected acute myocardial infarction.
The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...
A 12-lead ECG showing paroxysmal supraventricular tachycardia at about 180 beats per minute. Subtypes of SVT can often be distinguished by their electrocardiogram (ECG) characteristics. Most have a narrow QRS complex , although, occasionally, electrical conduction abnormalities may produce a wide QRS complex that may mimic ventricular ...
12-lead electrocardiogram showing ST-segment elevation (orange) in I, aVL and V1–V5 with reciprocal changes (blue) in the inferior leads, indicative of an anterior wall myocardial infarction. When there is a blockage of the coronary artery, there will be lack of oxygen supply to all three layers of cardiac muscle (transmural ischemia).
A 12-lead ECG showing atrial fibrillation at approximately 132 beats per minute Diagram of normal sinus rhythm as seen on ECG. In atrial fibrillation the P waves, which represent depolarization of the top of the heart, are absent. Diagnosis of atrial fibrillation is diagnosed on an electrocardiogram (ECG/EKG).
Under these criteria, an ECG is positive for an AMI in the presence of LBBB if any of the following criteria are present: ST deviation ≥1 mm (0.1 mV) concordant with QRS polarity in any ECG lead, thus including either: ST depression ≥1 mm (0.1 mV) concordant with QRS polarity, in any ECG lead.