    RVs in the US are equipped for 120 V 30 A or 240 V 50 A service, and use a cord to connect to a receptacle at the campsite, usually on a power pedestal with one or more receptacles providing 120 V 30 A (TT30R), 240 V 50 A (14-50R), or 120 V 15/20 A (5-20R) service.

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    In Europe, three-phase 230/400 V is most commonly used. However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current.

  4. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    For example, in North America, a unique split-phase system is used to supply to most premises that works by center tapping a 240 volt transformer. This system is able to concurrently provide 240 volts and 120 volts. Consequently, this allows homeowners to wire up both 240 V and 120 V circuits as they wish (as regulated by local building codes).

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  6. Why the stock market crushed expectations in 2024 - AOL

    www.aol.com/why-stock-market-crushed...

    The economy is doing great, evidenced by a solid pace of nearly 3% economic growth as measured by GDP, a labor market that seems to be in the sweet spot with record employment numbers and few ...

  7. AS/NZS 3112 - Wikipedia

    en.wikipedia.org/wiki/AS/NZS_3112

    The pins are arranged at 120° angles around a common midpoint, with the active and neutral centred 7.92 mm (5 ⁄ 16 in) from the midpoint, and the earth pin centred 10.31 mm (3 ⁄ 8 in) away. [5] A standard socket-outlet provides a nominal RMS voltage of 230 volts [2] at a maximum of 10 amps and always includes an earth connection ...