  2. Focused ion beam - Wikipedia

    en.wikipedia.org/wiki/Focused_ion_beam

    Focused ion beam, also known as FIB, is a technique used particularly in the semiconductor industry, materials science and increasingly in the biological field for site-specific analysis, deposition, and ablation of materials. A FIB setup is a scientific instrument that resembles a scanning electron microscope (SEM).

  3. Probe tip - Wikipedia

    en.wikipedia.org/wiki/Probe_Tip

    Focused ion and electron beam techniques for the fabrication of strong, stable, reproducible Si 3 N 4 pyramidal tips with 1.0 μm length and 0.1 μm diameter were reported by Russell in 1992. [6] Significant advancement also came through the introduction of micro-fabrication methods for the creation of precise conical or pyramidal silicon and ...

  4. Teodor Gotszalk - Wikipedia

    en.wikipedia.org/wiki/Teodor_Gotszalk

    The studies combine scanning probe microscopy, scanning electron microscopy and focused ion beam (SPM, SEM and FIB) techniques together with measurements of electrical, thermal, diffractive and optical properties of the structures. [4] Teodor Gotszalk has been a Corresponding member of the Polish Academy of Sciences since 2022. [5]

  5. List of materials analysis methods - Wikipedia

    en.wikipedia.org/wiki/List_of_materials_analysis...

    EBIC – Electron beam induced current (see IBIC: ion beam induced charge) EBS – Elastic (non-Rutherford) backscattering spectrometry (see RBS) EBSD – Electron backscatter diffraction; ECOSY – Exclusive correlation spectroscopy; ECT – Electrical capacitance tomography; EDAX – Energy-dispersive analysis of x-rays

  6. Transmission electron microscopy - Wikipedia

    en.wikipedia.org/wiki/Transmission_electron...

    Operating principle of a transmission electron microscope. Transmission electron microscopy (TEM) is a microscopy technique in which a beam of electrons is transmitted through a specimen to form an image. The specimen is most often an ultrathin section less than 100 nm thick or a suspension on a grid.

  7. Electron beam-induced deposition - Wikipedia

    en.wikipedia.org/wiki/Electron_beam-induced...

    Another method is ion-beam-induced deposition (IBID), where a focused ion beam is applied instead. Precursor materials are typically liquid or solid and gasified prior to deposition, usually through vaporization or sublimation, and introduced, at accurately controlled rate, into the high-vacuum chamber of the electron microscope. Alternatively ...

  8. Microprobe - Wikipedia

    en.wikipedia.org/wiki/Microprobe

    When the primary beam consists of accelerated electrons, the probe is termed an electron microprobe, when the primary beam consists of accelerated ions, the term ion microprobe is used. The term microprobe may also be applied to optical analytical techniques, when the instrument is set up to analyse micro samples or micro areas of larger specimens.

  9. Electron backscatter diffraction - Wikipedia

    en.wikipedia.org/wiki/Electron_backscatter...

    This may be followed by ion beam polishing, for final surface preparation. [23] [24] [25] Inside the SEM, the size of the measurement area determines local resolution and measurement time. [26] Usual settings for high-quality EBSPs are 15 nA current, 20 kV beam energy, 18 mm working distance, long exposure time, and minimal CCD pixel binning.