This developing system of international mutual recognition agreements between accreditation bodies has enabled accredited laboratories to achieve a form of international recognition, and allowed test data accompanying exported goods to be readily accepted on overseas markets amongst the countries which have already qualified as significant to ...
The Articles of Confederation, ratified by the colonies in 1781, provided: . The United States in Congress assembled shall also have the sole and exclusive right and power of regulating the alloy and value of coin struck by their own authority, or by that of the respective states—fixing the standards of weights and measures throughout the United States.
This NTEP Certificate of Conformance indicates that the device manufacturer has demonstrated the ability to meet applicable requirements for commercial weighing and measuring equipment in the United States as specified in Handbook 44: Specifications and Tolerances and Other Technical Requirements. NTEP certification is required in most states ...
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
The International Organization of Legal Metrology (French: Organisation Internationale de Métrologie Légale - OIML), is an intergovernmental organisation that was created in 1955 to promote the global harmonisation of the legal metrology procedures that underpin and facilitate international trade.
Calibration laboratories are accredited and provide calibration services to industry firms, which provides a traceability link back to the national metrology institute. Since the calibration laboratories are accredited, they give companies a traceability link to national metrology standards.
For example, in the case of a 60 tonne load cell, then specific test weights that measure in 5, 10, 20, 40 and 60 tonne increments may be used; a five step calibration process is usually sufficient for ensuring a device is accurately calibrated. Repeating this five-step calibration procedure 2-3 times is recommended for consistent results. [16]
The technicians who work in the PMEL will often specialize in one of these sections. The K-Sections are derived from the primary function of the TMDE. This is based upon the calibration authority. Most labs have three calibration sections divided into K1/K8, K5/K6 and K3/K4 that specialize in like test equipment.