enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...

  3. Wiggers diagram - Wikipedia

    en.wikipedia.org/wiki/Wiggers_diagram

    [1] [2] In the Wiggers diagram, the X-axis is used to plot time subdivided into the cardiac phases, while the Y-axis typically contains the following on a single grid: Blood pressure. Aortic pressure; Ventricular pressure; Atrial pressure; Ventricular volume; Electrocardiogram; Arterial flow (optional) Heart sounds (optional)

  4. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    ECGs are normally printed on a grid. The horizontal axis represents time and the vertical axis represents voltage. The standard values on this grid are shown in the adjacent image at 25mm/sec: [55] A small box is 1 mm × 1 mm and represents 0.1 mV × 0.04 seconds. A large box is 5 mm × 5 mm and represents 0.5 mV × 0.20 seconds.

  5. QRS complex - Wikipedia

    en.wikipedia.org/wiki/QRS_complex

    Schematic representation of a normal sinus rhythm ECG wave. Diagram showing how the polarity of the QRS complex in leads I, II, and III can be used to estimate the heart's electrical axis in the frontal plane. The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (ECG or EKG). It is usually ...

  6. Left axis deviation - Wikipedia

    en.wikipedia.org/wiki/Left_axis_deviation

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane.. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.

  7. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    If lead b is positive, the electrical heart axis can be estimated to lie within the quadrant between axis of lead a and lead b. A simple tool to quickly identify axis deviation (Figure 3) is the popular mnemonic; Reaching for Right Axis Deviation and Leaving for Left Axis Deviation. This refers to the appearance of leads I and II.

  8. Automated ECG interpretation - Wikipedia

    en.wikipedia.org/wiki/Automated_ECG_interpretation

    The manufacturing industries of ECG machines is now entirely digital, and many models incorporate embedded software for analysis and interpretation of ECG recordings with 3 or more leads. Consumer products, such as home ECG recorders for simple, 1-channel heart arrhythmia detection, also use basic ECG analysis, essentially to detect ...

  9. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    The shape forms an inverted equilateral triangle with the heart at the center. It is named after Willem Einthoven, who theorized its existence. [2] Einthoven used these measuring points, by immersing the hands and feet in pails of salt water, as the contacts for his string galvanometer, the first practical ECG machine. [3]