Consider the first triangular diagram below, which shows all possible mixtures of methane, oxygen and nitrogen. Air is a mixture of about 21 volume percent oxygen, and 79 volume percent inerts (nitrogen). Any mixture of methane and air will therefore lie on the straight line between pure methane and pure air – this is shown as the blue air-line.
Portable oxygen concentrator used with bottle humidifier. POCs operate on the same principle as a home concentrator, pressure swing adsorption. [6] The basic set up of a POC is a miniaturized air compressor, a cylinder filled containing the sieve, a pressure equalizing reservoir and valves and tubes.
To perform the test, one set of electrodes are placed on viable tissue (e.g. the chest) as a control and a second set is placed around the tissue in question (e.g. legs or feet). The electrodes may mildly heat the skin to increase blood flow into the area. Oxygen may also be given to the patient to see if that increases oxygen levels in the tissue.
An oxygen analyser for breathing gas mixtures for diving. The type of oxygen sensor used in most underwater diving applications is the electro-galvanic oxygen sensor, a type of fuel cell, which is sometimes called an oxygen analyser or ppO 2 meter. They are used to measure the oxygen concentration of breathing gas mixes such as nitrox and ...
The limiting oxygen concentration (LOC), [1] also known as the minimum oxygen concentration (MOC), [2] is defined as the limiting concentration of oxygen below which combustion is not possible, independent of the concentration of fuel. It is expressed in units of volume percent of oxygen. The LOC varies with pressure and temperature.
The equivalent air depth (EAD) is a way of approximating the decompression requirements of breathing gas mixtures that contain nitrogen and oxygen in different proportions to those in air, known as nitrox. [1] [2] [3]
Electro-galvanic fuel cell as used in a diving rebreather to measure the partial pressure of oxygen. Two oxygen cells as used by oxygen analysers for diving gas showing commonly used connectors. An electro-galvanic fuel cell is an electrochemical device which consumes a fuel to produce an electrical output by a chemical reaction.
The pin index safety system uses a face seal between the cylinder valve and the associated yoke clamp. There are two holes in specific positions on the cylinder valve body below the outlet port , in positions associated with the gas mixture, which prevent connection of the cylinder to a yoke or pressure regulator with a mis-matched set of pins.