Search results
Results from the WOW.Com Content Network
In medicine, a distal splenorenal shunt procedure (DSRS), also splenorenal shunt procedure and Warren shunt, [1] is a surgical procedure in which the distal splenic vein (a part of the portal venous system) is attached to the left renal vein (a part of the systemic venous system).
The ICD-10 Procedure Coding System (ICD-10-PCS) is a US system of medical classification used for procedural coding.The Centers for Medicare and Medicaid Services, the agency responsible for maintaining the inpatient procedure code set in the U.S., contracted with 3M Health Information Systems in 1995 to design and then develop a procedure classification system to replace Volume 3 of ICD-9-CM.
The revision of a shunt means to replace or make adjustments to all or part of the shunt, this also means that the location of the shunt may be changed therefore changing the category or type of shunt a patient has. For some patients with shunts, a revision or multiple revisions to the shunt may be required. This can be something minor, such as ...
A Peritoneovenous shunt: (also called Denver shunt) [2] is a shunt which drains peritoneal fluid from the peritoneum into veins, usually the internal jugular vein or the superior vena cava. It is sometimes used in patients with refractory ascites. It is a long tube with a non-return valve running subcutaneously from the peritoneum to the ...
Vascular access steal syndrome is a syndrome caused by ischemia (not enough blood flow) resulting from a vascular access device (such as an arteriovenous fistula or synthetic vascular graft–AV fistula) that was installed to provide access for the inflow and outflow of blood during hemodialysis.
Another leading cause of shunt failure is a blockage of the shunt at either the proximal or distal end. At the proximal end, the shunt valve can become blocked due to the buildup of excess protein in the CSF. The extra protein will collect at the point of drainage and slowly clog the valve. The shunt can also become blocked at the distal end if ...
The channel for the shunt is next created by inflating an angioplasty balloon within the liver along the tract created by the needle. The shunt is completed by placing a special mesh tube known as a stent or endograft to maintain the tract between the higher-pressure portal vein and the lower-pressure hepatic vein. After the procedure ...
The shunt also has a valve which serves to maintain one-way flow of the CSF and regulates the flow rate. The end with the catheter is placed in the third ventricle to drain the excess CSF and the other end is placed in the peritoneal cavity or atrium of the heart (making it a ventriculoperitoneal or ventriculoatrial shunt, respectively). The ...