Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...
Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)
[1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load. These include the global coordinates of the site and the size of the structure. [1] [5]
Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value, 154 millimetres (6 in) of rockwool or 84 millimetres (3 in) of rigid polyurethane foam panel would be required.
The U-value is used to refer to the amount of heat that can pass through a window, called thermal transmittance, with a lower score being better. [1] The U-factor of a window can often be found on the rating label of the window. Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units.
While these curtain wall systems are more energy-efficient than older, single-glazed versions, they are still significantly less efficient than opaque (solid) wall construction. [13] For example, nearly all curtain wall systems, thermally-broken or otherwise, have a U-value of 0.2 or higher, which is equivalent to an R-value of 5 or lower. [14]
Types of External cromatic wall insulation systems (EWI Systems pictured above) External wall insulation systems generally comprise firstly an insulation layer (an element which helps to achieve the requisite thermal performance); and secondly,a protected weatherproof finish (usually a render, although brick slips, [3] tiles, and decorative boards can also be used).
Formula Values d=1 millimeter Standard Atmospheric Pressure 0.0209 0.0235 0.0260 0.1 atmosphere 0.0209 0.0235 0.0259 0.01 atmospheres 0.0205 0.0230 0.0254 0.001 atmospheres 0.0178 0.0196 0.0212 0.0001 atmospheres 0.00760 0.00783 0.00800 10 −5 atmospheres 0.00113 0.00112 0.00111 10 −6 atmospheres 0.000119 0.000117 0.000115 10 −7 ...