Search results
Results from the WOW.Com Content Network
The centipoise is convenient because the viscosity of water at 20 °C is about 1 cP, and one centipoise is equal to the SI millipascal second (mPa·s). The SI unit of kinematic viscosity is square meter per second (m 2 /s), whereas the CGS unit for kinematic viscosity is the stokes (St, or cm 2 ·s −1 = 0.0001 m 2 ·s −1 ), named after Sir ...
The poise is often used with the metric prefix centi-because the viscosity of water at 20 °C (standard conditions for temperature and pressure) is almost exactly 1 centipoise. [3] A centipoise is one hundredth of a poise, or one millipascal-second (mPa⋅s) in SI units (1 cP = 10 −3 Pa⋅s = 1 mPa⋅s). [4] The CGS symbol for the centipoise ...
For kinematic viscosity, the SI unit is m^2/s. In engineering, the unit is usually Stoke or centiStoke, with 1 Stoke = 0.0001 m^2/s, and 1 centiStoke = 0.01 Stoke. For liquid, the dynamic viscosity is usually in the range of 0.001 to 1 Pascal-second, or 1 to 1000 centiPoise. The density is usually on the order of 1000 kg/m^3, i.e. that of water.
Conversions between units in the metric system are defined by their prefixes (for example, 1 kilogram = 1000 grams, 1 milligram = 0.001 grams) and are thus not listed in this article. Exceptions are made if the unit is commonly known by another name (for example, 1 micron = 10 −6 metre).
One can convert efflux time to kinematic viscosity by using an equation for each cup specification number, where t is the efflux time and ν is the kinematic viscosity in centistokes. Zahn Cup #1: ν = 1.1( t − 29)
The table below lists units supported by {{convert}}. More complete lists are linked for each dimension. For a complete list of all dimensions, see full list of units. {{Convert}} uses unit-codes, which are similar to, but not necessarily exactly the same as, the usual written abbreviation for a given unit. These unit-codes are displayed in ...
In this section our central macroscopic variables and parameters and their units are temperature [K], pressure [bar], molar mass [g/mol], low density (low pressure or dilute) gas viscosity [μP]. It is, however, common in the industry to use another unit for liquid and high density gas viscosity η {\displaystyle \eta } [cP].
Two marks (one above and one below the upper bulb) indicate a known volume. The time taken for the level of the liquid to pass between these marks is proportional to the kinematic viscosity. The calibration can be done using a fluid of known properties. Most commercial units are provided with a conversion factor.