The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...
Per UL Standard ANSI/UL 498, a receptacle (any color) with an orange triangle, is an isolated ground (IG) device, where the grounding pin of the receptacle is connected to ground independently of the frame of the receptacle and wiring outlet box. This is also a requirement of the National Electrical Code (NFPA 70), Article 406.
A series circuit with a voltage source (such as a battery, or in this case a cell) and three resistance units. Two-terminal components and electrical networks can be connected in series or parallel. The resulting electrical network will have two terminals, and itself can participate in a series or parallel topology.
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...
A graphic representation of a daisy chain A daisy garland, a chain of daisy flowers A series of devices connected in a daisy chain layout. In electrical and electronic engineering, a daisy chain is a wiring scheme in which multiple devices are wired together in sequence or in a ring, [1] similar to a garland of daisy flowers. Daisy chains may ...
In the late 1960s, a device specification known as CU/AL (meaning copper-aluminum) was created that specified standards for devices intended for use with aluminum wire. Some of these devices used larger undercut screw terminals to more securely hold the wire. Special CO/ALR-rated wall outlet and wall switch
When installed as the first outlet on a branch circuit, AFCI receptacles provide series arc protection for the entire branch circuit. They also provide parallel arc protection for the branch circuit starting at the AFCI receptacle. Unlike AFCI breakers, AFCI receptacles may be used on any wiring system regardless of the panel.
Telephone wiring is required between the telephone company's service entrance and locations throughout the home. Often a home will have telephone outlets in the kitchen, study, living room or bedrooms for convenience. Telephone company regulations may limit the total number of telephones that can be in use at one time.