Search results
Results from the WOW.Com Content Network
A high-voltage current transformer may contain several cores, each with a secondary winding, for different purposes (such as metering circuits, control, or protection). [7] A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer.
Class 0.5 is an ANSI C12.20 accuracy class for electric meters with absolute accuracy better than ± 0.5% of the nominal full scale reading. [1] Typically, a class specifies accuracy at a number of points, with the absolute accuracy at lower values being better than the nominal "percentage of full scale" accuracy.
Ideally the measuring device should not affect the circuit parameters i.e., the internal impedance of the ammeter should be zero (no voltage drop over the ammeter) and the internal impedance of the voltmeter should be infinite (no current through the voltmeter). However, in actual case, ammeters have a low but non zero impedance and voltmeters ...
The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit. Instrument transformers may also be used as an isolation transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.
In AC circuits, a current transformer can be used to convert the large current in the main circuit into a smaller current more suited to a meter. Some designs of transformer are able to directly convert the magnetic field around a conductor into a small AC current, typically either 1 A or 5 A at full rated current, that can be easily read by a ...
Common circuit diagram symbols (US ANSI symbols) An electronic symbol is a pictogram used to represent various electrical and electronic devices or functions, such as wires, batteries, resistors, and transistors, in a schematic diagram of an electrical or electronic circuit. These symbols are largely standardized internationally today, but may ...
A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.
A Rogowski coil is a toroid of wire used to measure an alternating current I(t) through a cable encircled by the toroid. The picture shows a Rogowski coil encircling a current-carrying cable. The output of the coil, v(t), is connected to a lossy integrator circuit to obtain a voltage V out (t) that is proportional to I(t).