Search results
Results from the WOW.Com Content Network
While natural ventilation methods may be effective, such as air outlets being installed closer to the ground, mechanical ventilation is often preferred for taller structures or in buildings with limited space. Smoke extraction is a key consideration in new constructions and must be evaluated in design stages. [3]
For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed ...
In order for ventilation to be effective, there must be exchange between outdoor air and room air. A common method for measuring ventilation effectiveness is to use a tracer gas. [6] The first step is to close all windows, doors, and openings in the space. Then a tracer gas is added to the air.
Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...
Ventilative cooling is the use of natural or mechanical ventilation to cool indoor spaces. [1] The use of outside air reduces the cooling load and the energy consumption of these systems, while maintaining high quality indoor conditions; passive ventilative cooling may eliminate energy consumption.
A03 Ventilation Design topic, the WELL assured building to have existing or new mechanical ventilation systems following ASHRAE 62.1-2 or EN standard 16798-1 or AS 1668.2 or CIBSE Guide A: Environmental Design. Naturally ventilation can also be used without mechanical ventilation system if the design follows Natural Ventilation Procedure in ...
English: A schematic showing the natural ventilation used in the Eastgate building in Harare. Note that the construction materials are special too; eg heat absorbing materials. References for the design obtained from this book (room ventilation), and this site (building construction). Similar designs could possibly be used in underground ...
The application of trickle vents in naturally-ventilated spaces can help contribute to IEQ Credit 2 under the LEED green building rating system. LEED EA Credit 2 references CIBSE Applications Manual 10, which provides advice on the design of naturally-ventilated spaces, recommending the installation of trickle vents in naturally-ventilated spaces.