GC–MS is used for the analysis of unknown organic compound mixtures. One critical use of this technology is the use of GC–MS to determine the composition of bio-oils processed from raw biomass. [29] GC–MS is also utilized in the identification of continuous phase component in a smart material, magnetorheological (MR) fluid. [30]
The Westgard rules are a set of statistical patterns, each being unlikely to occur by random variability, thereby raising a suspicion of faulty accuracy or precision of the measurement system. They are used for laboratory quality control , in "runs" consisting of measurements of multiple samples.
Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]
[3] [4] The most common approach for accounting for matrix effects is to build a calibration curve using standard samples with known analyte concentration and which try to approximate the matrix of the sample as much as possible. [2] This is especially important for solid samples where there is a strong matrix influence. [5]
Westgard rules are commonly used to analyse data in Shewhart control charts. Westgard rules are used to define specific performance limits for a particular assay (test) and can be used to detect both random and systematic errors. Westgard rules are programmed into automated analyzers to determine when an analytical run should be rejected. These ...
For example, GC Image was the first software developed for two dimensional gas chromatography. Some software [15] packages are used in addition to the normal GC (or GC-MS) packages while others are built as a complete platform, [16] [17] controlling all aspects of the analysis. The new and different way of presenting and evaluating data offers ...
Headspace gas chromatography uses headspace gas—from the top or "head" of a sealed container containing a liquid or solid brought to equilibrium [1] —injected directly onto a gas chromatographic column for separation and analysis. In this process, only the most volatile (most readily existing as a vapor) substances make it to the column. [2]
The detection limit for electron capture detectors is 5 femtograms per second (fg/s) and the detector commonly exhibits a 10,000-fold linear range. [ citation needed ] This made it possible to detect halogenated compounds such as pesticides and CFCs , even at levels of only one part per trillion ( ppt ), thus revolutionizing our understanding ...