enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  3. Specific fan power - Wikipedia

    en.wikipedia.org/wiki/Specific_fan_power

    In reality the fan system efficiency is often in the range 0 to 60% (i.e. <); it is lowest for small fans or inefficient operating points (e.g. throttled flow or free-flow). The efficiency is a function of the total losses in the fan system, including aerodynamic losses in the fan, friction losses in the drive (e.g. belt), losses in the ...

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The cooling load temperature difference (CLTD) calculation method, also called the cooling load factor (CLF) or solar cooling load factor (SCL) method, is a method of estimating the cooling load or heating load of a building.

  5. Centrifugal fan - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_fan

    A centrifugal fan is a mechanical device for moving air or other gases in a direction at an angle to the incoming fluid. Centrifugal fans often contain a ducted housing to direct outgoing air in a specific direction or across a heat sink; such a fan is also called a blower, blower fan, or squirrel-cage fan (because it looks like a hamster wheel).

  6. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    Mechanical ventilation systems may include supply fans (which push outdoor air into a building), exhaust [3] fans (which draw air out of a building and thereby cause equal ventilation flow into a building), or a combination of both (called balanced ventilation if it neither pressurizes nor depressurizes the inside air, [3] or only slightly ...

  7. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air. This is not the same as pumping a constant mass of air. Again, the fan will pump the same volume, though not mass, at any other air ...

  8. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Q = Volumetric flow rate of air in cubic feet per minute (cfm) Vol = Space volume L × W × H, in cubic feet; In metric units = where: ACPH = number of air changes per hour; higher values correspond to more ventilation; Q = Volumetric flow rate of air in liters per second (L/s)

  9. Axial fan design - Wikipedia

    en.wikipedia.org/wiki/Axial_fan_design

    An axial fan is a type of fan that causes gas to flow through it in an axial direction, parallel to the shaft about which the blades rotate. The flow is axial at entry and exit. The fan is designed to produce a pressure difference, and hence force, to cause a flow through the fan. Factors which determine the performance of the fan include the ...