The BSA-recommended procedures provide a "best practice" test protocol for professionals to follow, increasing validity and allowing standardisation of results across Britain. [ 8 ] In the United States, the American Speech–Language–Hearing Association (ASHA) published Guidelines for Manual Pure-Tone Threshold Audiometry in 2005.
The result of the test is an audiogram diagram which plots a person's hearing sensitivity at the tested frequencies. On an audiogram an "x" plot represents the softest threshold heard at each specific frequency in the left ear, and an "o" plot represents the softest threshold heard at each specific frequency in the right ear.
An audiogram is a graph that shows the audible threshold for standardized frequencies as measured by an audiometer. The Y axis represents intensity measured in decibels (dB) and the X axis represents frequency measured in hertz (Hz). [ 1 ]
The most commonly used assessment of hearing is the determination of the threshold of audibility, i.e. the level of sound required to be just audible. This level can vary for an individual over a range of up to 5 decibels from day to day and from determination to determination, but it provides an additional and useful tool in monitoring the ...
Portable audiometer Maico, circa 1960s. An audiometer typically transmits recorded sounds such as pure tones or speech to the headphones of the test subject at varying frequencies and intensities, and records the subject's responses to produce an audiogram of threshold sensitivity, or speech understanding profile.
A tone at the frequency of 4000 Hz is presented for 60 seconds at an intensity of 5 decibels above the patient's absolute threshold of hearing. If the patient stops hearing the tone before 60 seconds, the intensity level is increased by another 5 decibels with the procedure repeated until the tone can be heard for the full 60 seconds or until no decibel level can be found where the tone can be ...
Some procedures use a series of trials, with each trial using the 'single-interval "yes"/"no" paradigm'. This means that sound may be present or absent in the single interval, and the listener has to say whether they thought the stimulus was there. When the interval does not contain a stimulus, it is called a "catch trial". [4]
Real ear measurement is the measurement of sound pressure level in a patient's ear canal developed when a hearing aid is worn. It is measured with the use of a silicone probe tube inserted in the canal connected to a microphone outside the ear and is done to verify that the hearing aid is providing suitable amplification for a patient's hearing loss. [2]