Search results
Results from the WOW.Com Content Network
Figure 2 gives an example; in this example, the two x-intercepts differ by about 0.2 mL but this is a small discrepancy, given the large equivalence volume (0.5% error). Similar equations can be written for the titration of a weak base by strong acid (Gran, 1952; Harris, 1998).
A typical titration curve of a diprotic acid, oxalic acid, titrated with a strong base, sodium hydroxide.Both equivalence points are visible. Titrations are often recorded on graphs called titration curves, which generally contain the volume of the titrant as the independent variable and the pH of the solution as the dependent variable (because it changes depending on the composition of the ...
The volumetric titration is based on the same principles as the coulometric titration, except that the anode solution above now is used as the titrant solution. The titrant consists of an alcohol (ROH), base (B), SO 2 and a known concentration of I 2. Pyridine has been used as the base in this case. One mole of I 2 is consumed for each mole of ...
The word "titration" descends from the French word titrer (1543), meaning the proportion of gold or silver in coins or in works of gold or silver; i.e., a measure of fineness or purity. Tiltre became titre, [4] which thus came to mean the "fineness of alloyed gold", [5] and then the "concentration of a substance in a given sample". [6]
Titration of a standard solution using methyl orange indicator. Titrate is in Erlenmeyer flask, titrant is in burette. acid + base → salt + water. For example: HCl + NaOH → NaCl + H 2 O. Acidimetry is the specialized analytical use of acid-base titration to determine the concentration of a basic (alkaline) substance using standard acid.
The term also has two other, conflicting meanings. In titration, the titer is the ratio of actual to nominal concentration of a titrant, e.g. a titer of 0.5 would require 1/0.5 = 2 times more titrant than nominal. This is to compensate for possible degradation of the titrant solution.
where R 0 is the initial amount of R in the titration vessel, v 0 is the initial volume, [R] is the concentration of R in the burette and v i is the volume added. The burette concentration of a reactant not present in the burette is taken to be zero. In general, solving these nonlinear equations presents a formidable challenge because of the ...
Coupled to high resolution electronics, the best thermometric titration systems can resolve temperatures to 10 −5 K. Sharp equivalence points have been obtained in titrations where the temperature change during the titration has been as little as 0.001K. The technique can be applied to essentially any chemical reaction in a fluid where there ...