enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Diaphragm pump - Wikipedia

    en.wikipedia.org/wiki/Diaphragm_pump

    The basic working principle of an air-operated double diaphragm pump. Cross-section sketch of diaphragm fuel pump Air-operated double diaphragm pump. A diaphragm pump (also known as a Membrane pump) is a positive displacement pump that uses a combination of the reciprocating action of a rubber, thermoplastic or teflon diaphragm and suitable valves on either side of the diaphragm (check valve ...

  3. Pressure switch - Wikipedia

    en.wikipedia.org/wiki/Pressure_switch

    Switch enclosures may also be required to be weatherproof, corrosion resistant, or submersible. An electronic pressure switch incorporates some variety of pressure transducer (strain gauge, capacitive element, or other) and an internal circuit to compare the measured pressure to a set point. Such devices may provide improved repeatability ...

  4. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    Adjusting is the final setting of balancing devices such as dampers and valves, adjusting fan speeds and pump impeller sizes, in addition to automatic control devices such as thermostats and pressure controllers to achieve maximum specified system performance and efficiency during normal operation.

  5. Dry running protection - Wikipedia

    en.wikipedia.org/wiki/Dry_running_protection

    There are three different methods for detection of water shortage: Pressure switch on suction manifold or float switch/electrode relay in the supply tank: Dry-running protection with pressure/level switch. Measurement of inlet pressure in the suction manifold by means of an analogue pressure transmitter: Dry-running protection with pressure ...

  6. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.

  7. Pressure tank - Wikipedia

    en.wikipedia.org/wiki/Pressure_tank

    The pressure switch turns the water pump on when it senses a pressure that is less than P lo and turns it off when it senses a pressure greater than P hi. While the pump is on, the pressure tank fills up. The pressure tank is then depleted as it supplies water in the specified pressure range to prevent "short-cycling", in which the pump tries ...

  8. AOL

    login.aol.com/?lang=fr-FR&intl=fr

    x. AOL fonctionne mieux avec les dernières versions des navigateurs. Vous utilisez un navigateur obsolète ou non pris en charge, et certaines fonctionnalités de AOL risquent de ne pas fonctionner correctement.

  9. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60192 Low-pressure sodium vapour lamps – Performance specifications; IEC 60193 Hydraulic turbines, storage pumps and pump-turbines – Model acceptance tests; IEC 60194 Printed board design, manufacture and assembly – Terms and definitions; IEC 60195 Method of measurement of current noise generated in fixed resistors