enow.com Web Search

  1. Ads

    related to: autofill valve boiler control

Search results

  1. Results from the WOW.Com Content Network
  2. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    If the valve body is filled with water, the float moves upwards and closes the valve. If air collects in the valve body, the waterline lowers, as does the float, and the valve opens to release it. [4] To give more sealing force on the valve, the float generally works the valve through a lever.

  3. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    Traditional control valves make it inevitable. As we size a control valve, the K v calculated almost certainly will not match the K v of the nearest appropriate valve. For example, a K v calculation of 4.5 m 3 /h would most likely lead to the selection of a valve with a K v = 6.3 m 3 /h. This means the valve is capable of delivering 40% more ...

  4. Control loop - Wikipedia

    en.wikipedia.org/wiki/Control_loop

    A control loop is the fundamental building block of control systems in general and industrial control systems in particular. It consists of the process sensor, the controller function, and the final control element (FCE) which controls the process necessary to automatically adjust the value of a measured process variable (PV) to equal the value of a desired set-point (SP).

  5. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure , temperature , and liquid level.

  6. Glossary of boiler terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_boiler_terms

    A non-return valve allowing atmospheric air into the boiler, if a cold boiler reduces its internal pressure on cooling down. This avoids the risk of damage to some types, if their pressure loads are reversed. Few boilers are fitted with these, although the feedwater clack valve usually has a similar effect. Vertical boiler Water-level Water-wall

  7. OpenTherm - Wikipedia

    en.wikipedia.org/wiki/OpenTherm

    OpenTherm was founded in 1996 because multiple manufacturers needed a simple-to-use communicating system between room controller and boiler. It had to run, like the existing controllers, over the existing two wires, not polarity sensitive, without the use of batteries.

  1. Ads

    related to: autofill valve boiler control