ISO 14644 Standards were first formed from the US Federal Standard 209E Airborne Particulate Cleanliness Classes in Cleanrooms and Clean Zones. The need for a single standard for cleanroom classification and testing was long felt. After ANSI and IEST petitioned to ISO for new standards, the first document of ISO 14644 was published in 1999, ISO ...
Cleanrooms have defined particle count limits. Aerosol particle counters are used to test and classify a cleanroom to ensure its performance is up to a specific cleanroom classification standard. Several standards exist for cleanroom classification. The most frequently referred to classification is from the United States.
The air then leaves through exhaust grills. The advantage of this approach is the lower cost. The disadvantages are comparatively shorter HEPA fan filter life, worse particle counts than a recirculating cleanroom, and that it cannot accommodate air conditioning.
The test cleanroom must have a low-turbulence airflow (often known as laminar in this context) in order to prove high air cleanliness classes and also accurately locate particle sources. Particle counters are utilized as measurement devices in order to determine particulate contamination with regard to geometrical size, quantity, distribution ...
FED-STD-209 E Airborne Particulate Cleanliness Classes in Cleanrooms and Cleanzones was a federal standard concerning classification of air cleanliness, intended for use in environments like cleanrooms. The standard based its classifications on the measurement of airborne particles. [1]
ISO 16232-6:2007 Part 6: Particle mass determination by gravimetric analysis; ISO 16232-7:2007 Part 7: Particle sizing and counting by microscopic analysis; ISO 16232-8:2007 Part 8: Particle nature determination by microscopic analysis; ISO 16232-9:2007 Part 10: Particle sizing and counting by automatic light extinction particle counter
IEST-G-CC035.1: Design Considerations for AMC Filtration Systems in Cleanrooms; IEST-CC036.1: Testing Fan Filter Units; IEST-RP-CC042.1: Sizing and Counting of Submicrometer Liquid-borne Particles Using Optical Discrete-Particle Counters; IEST-RP-CC044.1: Vacuum Cleaning Systems for Use in Cleanrooms and Other Controlled Environments
The defined particle size ranges are 0.09–1.0 μm for smoke, 0.5–3 μm for dust, and 5–11 μm for pollen. AHAM recommends following their '2/3' rule. Air filters should be chosen for rooms so that the value of its smoke CADR is equal to or greater than 2/3 the room area in units of square feet (valid for rooms up to 8-foot (2.4 m) in ...