Search results
Results from the WOW.Com Content Network
Bosworth fracture: David M. Bosworth: fracture of distal fibula with posterior dislocation of the proximal fibula behind the tibia: severe external rotation of the foot "Bosworth fracture dislocation". Medcyclopaedia. GE. Boxer's fracture: Boxers: fracture at the neck of the fifth metacarpal: punching solid object
A traction splint most commonly refers to a splinting device that uses straps attaching over the pelvis or hip as an anchor, a metal rod(s) to mimic normal bone stability and limb length, and a mechanical device to apply traction (used in an attempt to reduce pain, realign the limb, and minimize vascular and neurological complication) to the limb.
In medicine, the Ilizarov apparatus is a type of external fixation apparatus used in orthopedic surgery to lengthen or to reshape the damaged bones of an arm or a leg; used as a limb-sparing technique for treating complex fractures and open bone fractures; and used to treat an infected non-union of bones, which cannot be surgically resolved.
The Maisonneuve fracture is a spiral fracture of the proximal third of the fibula associated with a tear of the distal tibiofibular syndesmosis and the interosseous membrane. There is an associated fracture of the medial malleolus or rupture of the deep deltoid ligament of the ankle .
A tib-fib fracture is a fracture of both the tibia and fibula of the same leg in the same incident. In 78% of cases, a fracture of the fibula is associated with a tibial fracture. [6] Since the fibula is smaller and weaker than the tibia, a force strong enough to fracture the tibia often fractures the fibula as well. Types include:
X-ray showing the proximal portion of a fractured tibia with an intramedullary nail Proximal femur nail with locking and stabilisation screws for treatment of femur fractures of left thigh An intramedullary rod , also known as an intramedullary nail (IM nail) or inter-locking nail or Küntscher nail (without proximal or distal fixation), is a ...
Implant that has been used for fixation of a broken wrist. Closed reduction internal fixation (CRIF) is reduction without any open surgery, followed by internal fixation. It appears to be an acceptable alternative in unstable distressed lateral condylar fractures of the humerus in children, but if fracture displacement after closed reduction exceeds 2 mm, open reduction and internal fixation ...
The sliding screw plate (dynamic compression screw, dynamic hip screw) may be used to treat intertrochanteric fractures as well as other injuries. This device consists of a lag screw and a side plate with a barrel. The sliding screw telescopes and provides fixation while allowing impaction to occur at the fracture during healing and weight ...