Modern micrometer with a reading of 1.639 ± 0.005 mm. Assuming no zero error, this is also the measurement. (One may need to enlarge the image to read it.) Outside, inside, and depth micrometers. The outside micrometer has a unit conversion chart between fractional and decimal inch measurements etched onto the frame
A depth gauge is an instrument for measuring depth below a vertical reference surface. They include depth gauges for underwater diving and similar applications. A diving depth gauge is a pressure gauge that displays the equivalent depth below the free surface in water. The relationship between depth and pressure is linear and accurate enough ...
ocean depth feeler gauge: gap widths forward looking infrared (FLIR) detects infrared energy (heat)converts it into an electronic signal, which is then processed to produce a thermal image on a video monitor and perform temperature calculations. framing square: right angles in construction frequency counter: frequency of alternating current ...
A digital sensor system consists of the sensor itself, a cable, and a transmitter. The differences with analog sensor systems are: a) The sensor has an electronic chip. The measuring signal is directly converted into a digital signal inside the sensor. The data transmission through the cable is also digital. This digital data transmission is ...
Each axis has a sensor that monitors the position of the probe on that axis, with typical accuracy in the order of microns. When the probe contacts (or otherwise detects) a particular location on the object, the machine samples the axis position sensors, thus measuring the location of one point on the object's surface, as well as the 3 ...
Digital calipers have zero set buttons, for quick recalibration. Vernier, dial and digital calipers can be used with accessories that extend their usefulness. Examples are a base that extends their usefulness as a depth gauge and a jaw attachment that all allows measuring the center distance between holes.
Manual deformation monitoring is the operation of sensors or instruments by hand or manual downloading of collected data from deformation monitoring instruments. Automatic deformation monitoring operation of a group of software and hardware elements for deformation monitoring that, once set up, does not require human input to function.
a flat steel block in the surface of which are two flat-bottomed grooves varying uniformly in depth from a maximum at one end of the block to zero near the other end. Groove depth is graduated on the block according to one or more scales used for measuring particle size. Most gages will have one scale marked in either mils or micrometers. Load cell