Search results
Results from the WOW.Com Content Network
The van Deemter equation is a hyperbolic function that predicts that there is an optimum velocity at which there will be the minimum variance per unit column length and, thence, a maximum efficiency. The van Deemter equation was the result of the first application of rate theory to the chromatography elution process.
A review by Berthod [19] studied the combined theories presented above and applied the Knox equation to independently determine the cause of the reduced efficiency. The Knox equation is commonly used in HPLC to describe the different contributions to overall band broadening of a solute. The Knox equation is expressed as: h = An^(1/3)+ B/n + Cn ...
HPLC has many applications in both laboratory and clinical science. It is a common technique used in pharmaceutical development, as it is a dependable way to obtain and ensure product purity. [59] While HPLC can produce extremely high quality (pure) products, it is not always the primary method used in the production of bulk drug materials. [60]
Convection of the sample occurs by laminar flow, in which the linear velocity of the sample at the tube's walls is zero, while the sample at the center of the tube moves with a linear velocity twice that of the carrier stream. The result is the parabolic flow profile, before the sample passes through a detector to a waste container.
From the equation above, we need to know the area of contact and the velocity gradient. Think of the lamina as a ring of radius r , thickness dr , and length Δ x . The area of contact between the lamina and the faster one is simply the surface area of the cylinder: A = 2π r Δ x .
Darcy's law is an equation that describes the flow of a fluid flow trough a porous medium and through a Hele-Shaw cell.The law was formulated by Henry Darcy based on results of experiments [1] on the flow of water through beds of sand, forming the basis of hydrogeology, a branch of earth sciences.
Capillary electrochromatography (CEC) combines the principles used in HPLC and CE. The mobile phase is driven across the chromatographic bed using electroosmosis instead of pressure (as in HPLC). Electroosmosis is the motion of liquid induced by an applied potential across a porous material, capillary tube, membrane or any other fluid conduit.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]