The pigging installation shown (right) is known as an Above Ground Installation (AGI). It is part of the UK's National Transmission System for natural gas. It shows two pig launcher/ receivers at the end of two 610-millimetre (24 in) diameter pipelines that carry gas under the River Thames, between East Tilbury in Essex and Shorne in Kent.
The primary purpose of leak detection systems (LDS) is to help pipeline controllers to detect and localize leaks. LDS provide alarms and display other related data to the pipeline controllers to assist decision-making. Pipeline leak detection systems can also enhance productivity and system reliability thanks to reduced downtime and inspection ...
Explosive vapor detectors (EVD) are explosives detection instruments whose principle of operation is the selective analysis of collected vapor samples from the air, in contrast to explosives trace detectors (ETD) which require the physical collection of particulate samples from surfaces.
The leak is releasing up to 110,000 pounds of gas per hour. An underground well-casing might have failed, pushing the pressurized gas to the surface. Severe natural gas leak in Los Angeles County ...
A gas detector can sound an alarm to operators in the area where the leak is occurring, giving them the opportunity to leave. This type of device is important because there are many gases that can be harmful to organic life, such as humans or animals. Gas detectors can be used to detect combustible, flammable and toxic gases, and oxygen depletion.
A tracer-gas leak testing method is a nondestructive testing method that detects gas leaks.A variety of methods with different sensitivities exist. Tracer-gas leak testing is used in the petrochemical industry, the automotive industry, the construction industry [1] and in the manufacture of semiconductors, among other uses.
The heating value depends on the source of gas that is used and the process that is used to liquefy the gas. The range of heating value can span ±10 to 15 percent. A typical value of the higher heating value of LNG is approximately 50 MJ/kg or 21,500 BTU/lb. [2] A typical value of the lower heating value of LNG is 45 MJ/kg or 19,350 BTU/lb.
A liquefied natural gas (LNG) spill can happen during an accident or an intentional act. LNG is normally stored and transported in liquid form at a temperature of approximately −162 °C (−260 °F). If this cooled liquid is released from a storage facility, pipeline, or LNG transport ship, then it begins to warm.