Methods of air removal include: Downward displacement (or gravity-type): As steam enters the chamber, it fills the upper areas first as it is less dense than air. This process compresses the air to the bottom, forcing it out through a drain which often contains a temperature sensor. Only when air evacuation is complete does the discharge stop.
This method is a faster process than dry heat sterilization. Steam sterilization is performed using an autoclave, sometimes called a converter or steam sterilizer. The object or liquid is placed in the autoclave chamber, which is then sealed and heated using pressurized steam to a temperature set point for a defined period of time.
Key to this form of sterilization is placement of the UV lamps and a good filtration system to remove the dead microorganisms. [105] For example, forced air systems by design impede line-of-sight, thus creating areas of the environment that will be shaded from the UV light.
A laminar flow cabinet blows unfiltered exhaust air towards the worker and is not safe for work with pathogenic agents, [2]: 13 [3] while a fume hood maintains negative pressure with constant exhaust to protect the user, but does not protect the work materials from contamination by the surrounding environment.
VHP is produced from a solution of liquid H 2 O 2 and water, by generators specifically designed for the purpose. These generators initially dehumidify the ambient air, then produce VHP by passing aqueous hydrogen peroxide over a vaporizer, and circulate the vapor at a programmed concentration in the air, typically from 140 ppm to 1400 ppm, depending on the infectious agent to be cleared. [6]
The proper time and temperature for dry heat sterilization is 160 °C (320 °F) for 2 hours or 170 °C (340 °F) for 1 hour, and in the case of High Velocity Hot Air sterilisers, 190°C (375°F) for 6 to 12 minutes. [3] Items should be dry before sterilization since water will interfere with the process.
Sterile dental instruments from hospital central supply (barcoded label indicating sterilization date, expiry date and contents). The central sterile services department (CSSD), also called sterile processing department (SPD), sterile processing, central supply department (CSD), or central supply, is an integrated place in hospitals and other health care facilities that performs sterilization ...
A biosafety cabinet (BSC)—also called a biological safety cabinet or microbiological safety cabinet—is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level.