enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    A high-voltage current transformer may contain several cores, each with a secondary winding, for different purposes (such as metering circuits, control, or protection). [7] A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer.

  3. Center tap - Wikipedia

    en.wikipedia.org/wiki/Center_tap

    Diagram of center-tapped transformer. In electronics, a center tap (CT) is a contact made to a point halfway along a winding of a transformer or inductor, or along the element of a resistor or a potentiometer. Taps are sometimes used on inductors for the coupling of signals, and may not necessarily be at the half-way point, but rather, closer ...

  4. Toroidal inductors and transformers - Wikipedia

    en.wikipedia.org/wiki/Toroidal_inductors_and...

    Thus, a toroidal inductor/transformer, radiates less electromagnetic interference (EMI) to adjacent circuits and is an ideal choice for highly concentrated environments. [3] Manufacturers have adopted toroidal coils in recent years to comply with increasingly strict international standards limiting the amount of electromagnetic field consumer ...

  5. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A current clamp uses a current transformer with a split core that can be easily wrapped around a conductor in a circuit. This is a common method used in portable current measuring instruments but permanent installations use more economical types of current transformer.

  6. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...

  7. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2. The centre-tapped side of T1 is connected between two of the phases on the three-phase side.

  8. Isolation transformer - Wikipedia

    en.wikipedia.org/wiki/Isolation_transformer

    In electronics testing and servicing, an isolation transformer is a 1:1 (under load) power transformer used for safety. Without it, exposed live metal in a device under test is at a hazardous voltage relative to grounded objects such as a heating radiator or oscilloscope ground lead (a particular hazard with some old vacuum-tube equipment with ...

  9. Voltage transformer - Wikipedia

    en.wikipedia.org/wiki/Voltage_transformer

    Transformer winding primary (usually high-voltage) connecting wires are of many types. They may be labeled as H 1, H 2 (sometimes H 0 if it is internally designed to be grounded) and X 1, X2 and sometimes an X 3 tap may be present. Sometimes a second isolated winding (Y 1, Y 2, Y 3) (and third (Z 1, Z 2, Z 3) may also be available on the same ...