Some types of resolvers include both types, with the 2-pole windings used for absolute position and the multipole windings for accurate position. Two-pole resolvers can usually reach angular accuracy up to about ±5 ′, whereas a multipole resolver can provide better accuracy, up to 10″ for 16-pole resolvers, to even 1″ for 128-pole resolvers.
These early machines used crudely designed field pole pieces with long magnetic circuits, wide pole gaps and narrow pole pieces that gave only a limited flux through the armature. These fields were usually horseshoe-shaped, with either permanent horseshoe magnets or else either one or two field coils at some distance from the poles.
A Dahlander motor (also known as a pole changing motor, dual- or two speed-motor) is a type of multispeed three-phase induction motor, in which the speed of the motor is varied by altering the number of poles; this is achieved by altering the wiring connections inside the motor.
In building wiring, multiway switching is the interconnection of two or more electrical switches to control an electrical load from more than one location.A common application is in lighting, where it allows the control of lamps from multiple locations, for example in a hallway, stairwell, or large room.
Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.
Single pole, single throw: One-way: Two-way: A simple on-off switch: The two terminals are either connected together or disconnected from each other. An example is a light switch. SPST-NO. Form A [4] Single pole, single throw, normally open A simple on-off switch. The two terminals are normally disconnected (open) and are closed when the switch ...
In control theory there are two main methods of analyzing feedback systems: the transfer function (or frequency domain) method and the state space method. When the transfer function method is used, attention is focused on the locations in the s-plane where the transfer function is undefined (the poles ) or zero (the zeroes ; see Zeroes and poles ).
By increasing the number of pole faces surrounding the Gramme ring, the ring can be made to cut across more magnetic lines of force in one revolution than a basic two-pole generator. Consequently, a four-pole generator could output twice the voltage of a two-pole generator, a six-pole generator could output three times the voltage of a two-pole ...