enow.com Web Search

  1. Ad

    related to: ceiling joists spans psf 3 equivalent

Search results

  1. Results from the WOW.Com Content Network
  2. Open web steel joist - Wikipedia

    en.wikipedia.org/wiki/Open_web_steel_joist

    The LH- and DLH-Series have been designed for the purpose of extending the use of joists to spans and loads in excess of those covered by Open Web Steel Joists, K-Series. LH-Series Joists have been standardized in depths from 18 inches (460 mm) through 48 inches (1,200 mm), for spans through 96 feet (29,000 mm).

  3. Joist - Wikipedia

    en.wikipedia.org/wiki/Joist

    A double floor is a floor framed with joists supported by larger timbers.. In traditional timber framing there may be a single set of joists which carry both a floor and ceiling called a single floor (single joist floor, single framed floor) or two sets of joists, one carrying the floor and another carrying the ceiling called a double floor (double framed floor).

  4. Trimmer (construction) - Wikipedia

    en.wikipedia.org/wiki/Trimmer_(construction)

    In light-frame construction, a trimmer is a timber or metal beam (joist) used to create an opening around a stairwell, skylight, chimney, and the like. Trimmers are installed parallel to the primary floor or ceiling joists and support headers , which run perpendicular to the primary joists.

  5. Double tee - Wikipedia

    en.wikipedia.org/wiki/Double_tee

    Diagram of double tee beam. A double tee or double-T beam is a load-bearing structure that resembles two T-beams connected to each other side by side. The strong bond of the flange (horizontal section) and the two webs (vertical members, also known as stems) creates a structure that is capable of withstanding high loads while having a long span.

  6. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    The distance between ribs is typically 915 mm (3 ft). [3] The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb ...

  7. American historic carpentry - Wikipedia

    en.wikipedia.org/wiki/American_historic_carpentry

    The joists are eliminated by the use of heavy planks saving time and strength of the timbers because the joists notches were eliminated. The beams are spaced 4 feet (1.2 m) to 18 feet (5.5 m) apart and the planks are 2 inches (5.1 cm) or more thick possibly with another layer of 1 inch (2.5 cm) on the top as the finished flooring could span ...

  8. I-beam - Wikipedia

    en.wikipedia.org/wiki/I-beam

    I-joists, I-beams engineered from wood with fiberboard or laminated veneer lumber, or both, are also becoming increasingly popular in construction, especially residential, as they are both lighter and less prone to warping than solid wooden joists. However, there has been some concern as to their rapid loss of strength in a fire if unprotected.

  9. Domestic roof construction - Wikipedia

    en.wikipedia.org/wiki/Domestic_roof_construction

    Heavier under purlins or purlin plates are used to support longer rafter spans. Tie beams, which may also serve as ceiling joists, are typically connected between the lower ends of opposite rafters to prevent them from spreading and forcing the walls apart. Collar beams or collar ties may be fixed higher up between opposite rafters for extra ...

  1. Ad

    related to: ceiling joists spans psf 3 equivalent