enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Synchronous motor - Wikipedia

    en.wikipedia.org/wiki/Synchronous_motor

    Synchronous motors use electromagnets as the stator of the motor which create a magnetic field that rotates in time with the oscillations of the current. The rotor with permanent magnets or electromagnets turns in step with the stator field at the same rate and as a result, provides the second synchronized rotating magnet field.

  3. V curve - Wikipedia

    en.wikipedia.org/wiki/V_curve

    If the field current is increased beyond this point, the armature current becomes leading, power factor decreases, and grows again. [4] The data from the V curves can be used to set up the synchronous motor to correct the power factor of the overall system, as the power factor of the motor can be changed by simply adjusting the field current. [3]

  4. Vector control (motor) - Wikipedia

    en.wikipedia.org/wiki/Vector_control_(motor)

    In vector control, an AC induction or synchronous motor is controlled under all operating conditions like a separately excited DC motor. [21] That is, the AC motor behaves like a DC motor in which the field flux linkage and armature flux linkage created by the respective field and armature (or torque component) currents are orthogonally aligned such that, when torque is controlled, the field ...

  5. Excitation (magnetic) - Wikipedia

    en.wikipedia.org/wiki/Excitation_(magnetic)

    A field coil may be connected in shunt, in series, or in compound with the armature of a DC machine (motor or generator). For a machine using field coils, as is the case in most large generators, the field must be established by a current in order for the generator to produce electricity.

  6. Synchronous impedance curve - Wikipedia

    en.wikipedia.org/wiki/Synchronous_impedance_curve

    Synchronous impedance curve (short-circuit characteristic curve), showing armature current as function of field current. The curve is obtained by rotating the generator at the rated RPM with the output terminals shorted and the output current going to 100% of the rated for the device (higher values are typically not tested to avoid overheating ...

  7. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    The sequence of events is similar for manual or automatic synchronization. The generator is brought up to approximate synchronous speed by supplying more energy to its shaft - for example, opening the valves on a steam turbine, opening the gates on a hydraulic turbine, or increasing the fuel rack setting on a diesel engine. The field of the ...

  8. Reactances of synchronous machines - Wikipedia

    en.wikipedia.org/wiki/Reactances_of_synchronous...

    Usually applied for transients after a short circuit current. Three states are considered: [5] the steady-state is the normal operating condition with the armature magnetic flux going through the rotor; the sub-transient state (″) is the one the generator enters immediately after the fault (short circuit). In this state the armature flux is ...

  9. Field coil - Wikipedia

    en.wikipedia.org/wiki/Field_coil

    A field coil is an electromagnet used to generate a magnetic field in an electro-magnetic machine, typically a rotating electrical machine such as a motor or generator. It consists of a coil of wire through which the field current flows.