  2. Magnetic particle inspection - Wikipedia

    en.wikipedia.org/wiki/Magnetic_particle_inspection

    Indirect magnetization occurs when no electric current is passed through the test object, but a magnetic field is applied from an outside source. The magnetic lines of force are perpendicular to the direction of the electric current, which may be either alternating current (AC) or some form of direct current (DC) (rectified AC).

  3. Electromagnetic testing - Wikipedia

    en.wikipedia.org/wiki/Electromagnetic_testing

    Magnetic particle inspection (MT or MPI) is a form of MFL where small magnetic particles in the form of a powder or liquid are sprayed on the magnetized steel test object and gather at surface-breaking cracks. Alternating current field measurement (ACFM) is similar to eddy current applied to steel. Its most common application is to detect and ...

  4. Epstein frame - Wikipedia

    en.wikipedia.org/wiki/Epstein_frame

    is the average magnetic path length = 0.94 (constant value) m {\displaystyle m~} is the mass of the sample in kilograms If all conditions are as defined in the standard, the standard deviation of the reproducibility of the values is not greater than 1.5% up to 1.5 T [ clarification needed ] for non-oriented electrical steel and up to 1.7 T for ...

  5. Magnetic flux leakage - Wikipedia

    en.wikipedia.org/wiki/Magnetic_flux_leakage

    The basic principle is that the magnetic field "leaks" from the steel at areas where there is corrosion or missing metal. To magnetize the steel, a powerful magnet is used. In an MFL (or Magnetic Flux Leakage) tool, a magnetic detector is placed between the poles of the magnet to detect the leakage field. Analysts interpret the chart recording ...

  6. Eddy-current testing - Wikipedia

    en.wikipedia.org/wiki/Eddy-current_testing

    Variations in the electrical conductivity and magnetic permeability of the test object, and the presence of defects causes a change in eddy current and a corresponding change in phase and amplitude that can be detected by measuring the impedance changes in the coil, which is a telltale sign of the presence of defects. [5]

  7. Magnetometer - Wikipedia

    en.wikipedia.org/wiki/Magnetometer

    However, magnetic torque magnetometry doesn't measure magnetism directly as all the previously mentioned methods do. Magnetic torque magnetometry instead measures the torque τ acting on a sample's magnetic moment μ as a result of a uniform magnetic field B, τ = μ × B. A torque is thus a measure of the sample's magnetic or shape anisotropy.

  8. Vibrating-sample magnetometer - Wikipedia

    en.wikipedia.org/wiki/Vibrating-sample_magnetometer

    The alternating magnetic field induces an electric field in the pickup coils of the VSM. [4] The current is proportional to the magnetization of the sample - the greater the induced current, the greater the magnetization. As a result, typically a hysteresis curve will be recorded [5] and from there the magnetic properties of the sample can be ...

  9. Magnetocardiography - Wikipedia

    en.wikipedia.org/wiki/Magnetocardiography

    If the magnetic field is measured using a multichannel device, a map of the magnetic field is obtained over the chest; from such a map, using mathematical algorithms that take into account the conductivity structure of the torso, it is possible to locate the source of the activity.