enow.com Web Search

  1. Ad

    related to: general compressibility factor chart for oxygen and carbon dioxide analyzer

Search results

  1. Results from the WOW.Com Content Network
  2. Compressibility factor - Wikipedia

    en.wikipedia.org/wiki/Compressibility_factor

    Once two of the three reduced properties are found, the compressibility chart can be used. In a compressibility chart, reduced pressure is on the x-axis and Z is on the y-axis. When given the reduced pressure and temperature, find the given pressure on the x-axis. From there, move up on the chart until the given reduced temperature is found.

  3. Orsat gas analyser - Wikipedia

    en.wikipedia.org/wiki/Orsat_gas_analyser

    ORSAT analyzer. An Orsat gas analyser or Orsat apparatus is a piece of laboratory equipment used to analyse a gas sample (typically fossil fuel flue gas) for its oxygen, carbon monoxide and carbon dioxide content. Although largely replaced by instrumental techniques, the Orsat remains a reliable method of measurement and is relatively simple to ...

  4. Van der Waals constants (data page) - Wikipedia

    en.wikipedia.org/wiki/Van_der_Waals_constants...

    Sulfur dioxide: 6.803 0.05636 Sulfur hexafluoride [2] 7.857 0.0879 Tetrachloromethane [2] 20.01 0.1281 Tetrachlorosilane [2] 20.96 0.1470 Tetrafluoroethylene [2] 6.954 0.0809 Tetrafluoromethane [2] 4.040 0.0633 Tetrafluorosilane [2] 5.259 0.0724 Tetrahydrofuran [2] 16.39 0.1082 Tin tetrachloride: 27.27 0.1642 Thiophene [2] 17.21 0.1058 Toluene ...

  5. Compressibility - Wikipedia

    en.wikipedia.org/wiki/Compressibility

    The compressibility factor is defined as = where p is the pressure of the gas, T is its temperature, and is its molar volume, all measured independently of one another. In the case of an ideal gas, the compressibility factor Z is equal to unity, and the familiar ideal gas law is recovered:

  6. Liquefaction of gases - Wikipedia

    en.wikipedia.org/wiki/Liquefaction_of_gases

    Many gases can be put into a liquid state at normal atmospheric pressure by simple cooling; a few, such as carbon dioxide, require pressurization as well. Liquefaction is used for analyzing the fundamental properties of gas molecules (intermolecular forces), or for the storage of gases, for example: LPG , and in refrigeration and air conditioning .

  7. Exhaust gas analyzer - Wikipedia

    en.wikipedia.org/wiki/Exhaust_gas_analyzer

    A lean mixture contains an excess of oxygen. The surplus oxygen will react with nitrogen to (oxides of nitrogen), if the temperature is high enough (around 1600 °C) for enough time to permit so. A rich mixture contains a deficit of oxygen. This makes it impossible for all fuel to combust completely to carbon dioxide and water vapour.

  8. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    Correcting to a reference carbon dioxide content [ edit ] The following equation can be used to correct a measured pollutant concentration in an emitted gas (containing a measured CO 2 content) to an equivalent pollutant concentration in an emitted gas containing a specified reference amount of CO 2 : [ 5 ]

  9. Capnography - Wikipedia

    en.wikipedia.org/wiki/Capnography

    Capnography is the monitoring of the concentration or partial pressure of carbon dioxide (CO 2) in the respiratory gases. Its main development has been as a monitoring tool for use during anesthesia and intensive care. It is usually presented as a graph of CO

  1. Ad

    related to: general compressibility factor chart for oxygen and carbon dioxide analyzer