  1. Results from the WOW.Com Content Network
  2. Permissible stress design - Wikipedia

    en.wikipedia.org/wiki/Permissible_stress_design

    The "factor" is sometimes called a factor of safety, although this is technically incorrect because the factor includes allowance for matters such as local stresses and manufacturing imperfections that are not specifically calculated; exceeding the allowable values is not considered to be good practice (i.e. is not "safe").

  3. Fatigue limit - Wikipedia

    en.wikipedia.org/wiki/Fatigue_limit

    The surface modifying factor, , is related to both the tensile strength, , of the material and the surface finish of the machine component. k S = a S u t b {\displaystyle k_{S}=aS_{ut}^{b}} Where factor a and exponent b present in the equation are related to the surface finish.

  4. Euler's critical load - Wikipedia

    en.wikipedia.org/wiki/Euler's_critical_load

    The critical load is the greatest load that will not cause lateral deflection (buckling). For loads greater than the critical load, the column will deflect laterally. The critical load puts the column in a state of unstable equilibrium. A load beyond the critical load causes the column to fail by buckling. As the load is increased beyond the ...

  5. Structural load - Wikipedia

    en.wikipedia.org/wiki/Structural_load

    Dead loads have small load factors, such as 1.2, because weight is mostly known and accounted for, such as structural members, architectural elements and finishes, large pieces of mechanical, electrical and plumbing (MEP) equipment, and for buildings, it's common to include a Super Imposed Dead Load (SIDL) of around 5 pounds per square foot ...

  6. Structural engineering theory - Wikipedia

    en.wikipedia.org/wiki/Structural_engineering_theory

    A load case is a combination of different types of loads with safety factors applied to them. A structure is checked for strength and serviceability against all the load cases it is likely to experience during its lifetime. Typical load cases for design for strength (ultimate load cases; ULS) are: 1.2 x Dead Load + 1.6 x Live Load

  7. Limit state design - Wikipedia

    en.wikipedia.org/wiki/Limit_state_design

    Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria. [ 1 ]

  8. Utilization factor - Wikipedia

    en.wikipedia.org/wiki/Utilization_factor

    Utilization factor (solid line) with blade-to-gas speed ratio. The utilization factor or use factor is the ratio of the time that a piece of equipment is in use to the total time that it could be in use. It is often averaged over time in the definition such that the ratio becomes the amount of energy used divided by the maximum possible to be used.

  9. Crack growth equation - Wikipedia

    en.wikipedia.org/wiki/Crack_growth_equation

    It is observed at low load ratios that the growth rate is most sensitive to microstructure and in low strength materials it is most sensitive to load ratio. [13] Regime B: At mid-range of growth rates, variations in microstructure, mean stress (or load ratio), thickness, and environment have no significant effects on the crack propagation rates.