In radio engineering and telecommunications, standing wave ratio (SWR) is a measure of impedance matching of loads to the characteristic impedance of a transmission line or waveguide. Impedance mismatches result in standing waves along the transmission line, and SWR is defined as the ratio of the partial standing wave 's amplitude at an ...
An SWR meter does not measure the actual impedance of a load (the resistance and reactance), but only the mismatch ratio. To measure the actual impedance requires an antenna analyzer or other similar RF measuring device. For accurate readings, the SWR meter itself must also match the line's impedance (typically 50 or 75 Ohms).
An antenna analyzer measuring SWR and complex impedance of a dummy load. MFJ-269, MFJ Enterprises Inc. An antenna analyzer or in British aerial analyser (also known as a noise bridge, RX bridge, SWR analyzer, or RF analyzer) is a device used for measuring the input impedance of antenna systems in radio electronics applications.
To adjust the matching network the simplest instrument to measure the degree of mismatch between the feedline and the antenna is called an SWR meter (standing wave ratio meter), which reports the standing wave ratio (SWR) on the line: The ratio of the adjacent maximum and minimum voltage or current on the line. A ratio of 1:1 indicates an ...
Our favorite decibel apps include: Decibel Pro, Decibel X, NIOSH SLM app (for iPhone), and Sound Meter & Noise Detector (for Android) Apple products allow passive alerts to help prevent exceeding ...
Cross-needle SWR meter on antenna tuner. It is a common misconception that a high standing wave ratio (SWR) per se causes loss. [3] A well-adjusted ATU feeding an antenna through a low-loss line may have only a small percentage of additional loss compared with an intrinsically matched antenna, even with a high SWR (4:1, for example). [21]
Figure 1. Waveguide slotted line. Slotted lines are used for microwave measurements and consist of a movable probe inserted into a slot in a transmission line.They are used in conjunction with a microwave power source and usually, in keeping with their low-cost application, a low cost Schottky diode detector and VSWR meter rather than an expensive microwave power meter.
A field strength meter is actually a simple receiver. The RF signal is detected and fed to a microammeter, which is scaled in dBμ. The frequency range of the tuner is usually within the terrestrial broadcasting bands. Some FS meters can also receive satellite (TVRO and RRO) frequencies.