Search results
Results from the WOW.Com Content Network
A vacuum insulated panel (VIP) is a form of thermal insulation consisting of a gas-tight enclosure surrounding a rigid core, from which the air has been evacuated. It is used in building construction, refrigeration units, and insulated shipping containers to provide better insulation performance than conventional insulation materials. [1] [2]
For example, a 4" pipe, with 1" of thermal insulation makes a 6" penetrant (1" pipe covering on each side of the pipe), plus two pipe sizes = an 8" sleeve, creating a 1" annulus. In case of insulated piping, the size of the insulation must be taken into account for the intended firestop certification listing.
Animation of heat-shrink tubing, before and after shrinking. Heat-shrink tubing (or, commonly, heat shrink or heatshrink) is a shrinkable plastic tube used to insulate wires, providing abrasion resistance and environmental protection for stranded and solid wire conductors, connections, joints and terminals in electrical wiring.
Heat-shrinkable sleeves are applied onto the cutback at the field weld or "field joint" during the construction of a pipeline. As described above, the heat-shrinkable sleeves have an adhesive that sticks the sleeve to the cutback and the factory applied mainline coating and also acts as a corrosion protective layer.
Multi-layer insulation (MLI) is thermal insulation composed of multiple layers of thin sheets and is often used on spacecraft and cryogenics. Also referred to as superinsulation, [ 1 ] MLI is one of the main items of the spacecraft thermal design , primarily intended to reduce heat loss by thermal radiation .
Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value (in K⋅m 2 /W) is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]
For instance, in some circumstances, heating pipework within a well-insulated building might not require insulation, as the heat that's "lost" (i.e., the heat that flows from the pipe to the surrounding air) may be considered “useful” for heating the building, as such "lost" heat would be effectively trapped by the structural insulation ...
The paper needs to be thin (30-40 g/m 2). A normal power cable needs more insulation and therefore paper with higher paper density is used, normally 60-190 g/m 2. The paper needs to be strong, elastic, uniform and free of holes or debris. These applications are being replaced by plastic insulation.