enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  3. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    In addition, a fault condition to a bootleg ground will not trip a GFCI breaker, nor protect a receptacle that is wired from the load side of a GFCI receptacle. [ 2 ] Before 1996, in the United States it was common to ground the frames of large 120/240-volt permanently-connected appliances (such as a clothes dryer or oven ) to neutral conductors.

  4. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    A branch type AFCI trips on 75 amperes of arcing current from the line wire to either the neutral or ground wire. A combination type adds series arcing detection to branch type performance. Combination type AFCIs trip on 5 amperes of series arcing. Dual-function AFCI GFCI (ground fault circuit interrupter) 110 volt receptacle circa 2016

  5. Electrical system design - Wikipedia

    en.wikipedia.org/wiki/Electrical_system_design

    One-line diagrams represent the three or four conductors of three-phase power circuits with one line. Wiring diagrams are sometimes made. These show and name the termination points and names of each conductor. In some systems, enough information can be put onto the schematics so that wiring diagrams are not needed.

  6. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    A wire break in the fault to load section, or in the earth to ground section, will disable operation of the ELCB. Requirement of an additional third wire from the load to the ELCB. Separate devices cannot be grounded individually. Any additional connection to Earth on the protected system can disable the detector.

  7. Electrical drawing - Wikipedia

    en.wikipedia.org/wiki/Electrical_drawing

    An electrical drawing is a type of technical drawing that shows information about power, lighting, and communication for an engineering or architectural project.Any electrical working drawing consists of "lines, symbols, dimensions, and notations to accurately convey an engineering's design to the workers, who install the electrical system on the job".

  8. After Week 1 clash, Commanders prepare to face ... - AOL

    www.aol.com/week-1-clash-commanders-prepare...

    At the line of scrimmage, Wagner said, the defense will check and the offense audible in return. “It’s just a fun game, and the whole world is watching,” Wagner said.

  9. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...