Search results
Results from the WOW.Com Content Network
The noise floor limits the smallest measurement that can be taken with certainty since any measured amplitude can on average be no less than the noise floor. A common way to lower the noise floor in electronics systems is to cool the system to reduce thermal noise, when this is the major noise source. In special circumstances, the noise floor ...
Friis formula or Friis's formula (sometimes Friis' formula), named after Danish-American electrical engineer Harald T. Friis, is either of two formulas used in telecommunications engineering to calculate the signal-to-noise ratio of a multistage amplifier. One relates to noise factor while the other relates to noise temperature.
The noise power from a simple load is equal to kTB, where k is the Boltzmann constant, T is the absolute temperature of the load (for example a resistor), and B is the measurement bandwidth. This makes the noise figure a useful figure of merit for terrestrial systems, where the antenna effective temperature is usually near the standard 290 K ...
This required difference in power levels of the signal and the noise floor is known as the signal-to-noise ratio (SNR). To establish the minimum detectable signal (MDS) of a receiver we require several factors to be known. Required signal-to-noise ratio (SNR) Detection bandwidth (BW) Temperature T 0 of the receiver system; Receiver noise figure ...
Using the formula for energy on a capacitor (E = 1 / 2 CV 2), mean noise energy on a capacitor can be seen to also be 1 / 2 C kT / C = kT / 2 . Thermal noise on a capacitor can be derived from this relationship, without consideration of resistance.
In the above formula, P is measured in units of power, such as watts (W) or milliwatts (mW), and the signal-to-noise ratio is a pure number. However, when the signal and noise are measured in volts (V) or amperes (A), which are measures of amplitude, [note 1] they must first be squared to obtain a quantity proportional to power, as shown below:
The Schottky formula assumes independent arrivals. Vacuum tubes exhibit shot noise because the electrons randomly leave the cathode and arrive at the anode (plate). A tube may not exhibit the full shot noise effect: the presence of a space charge tends to smooth out the arrival times (and thus reduce the randomness of the current).
The noise factor (a linear term) is more often expressed as the noise figure (in decibels) using the conversion: = The noise figure can also be seen as the decrease in signal-to-noise ratio (SNR) caused by passing a signal through a system if the original signal had a noise temperature of 290 K. This is a common way of expressing the noise ...