enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    By estimating the temperature of the cables, the safe long-term current-carrying capacity of the cables can be calculated. J. H. Neher and M. H. McGrath were two electrical engineers who wrote a paper in 1957 about how to calculate the capacity of current (ampacity) of cables. [1]

  3. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  4. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    The current-carrying capacity, or ampacity, of overhead lines starts with the type of conductor used. The conductor choice determines its electrical resistance and other physical parameters for dynamic line rating (DLR).

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.

  6. Power cable - Wikipedia

    en.wikipedia.org/wiki/Power_cable

    A power cable is an electrical cable, an assembly of one or more electrical conductors, usually held together with an overall sheath. The assembly is used for transmission of electrical power . Power cables may be installed as permanent wiring within buildings, buried in the ground, run overhead, or exposed.

  7. Extra-low voltage - Wikipedia

    en.wikipedia.org/wiki/Extra-low_voltage

    The higher current results in greater resistive losses in the cabling. Cable sizing must therefore consider maximum demand, voltage drop over the cable, and current-carrying capacity . Voltage drop is usually the main factor considered, but current-carrying capacity is as important when considering short, high-current runs such as between a ...

  8. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    Conductors installed so that air can freely move over them can be rated to carry more current than conductors run inside a conduit or buried underground. High ambient temperature may reduce the current rating of a conductor. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. A lower rating will ...

  9. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    The following are nominal current ratings for copper conductors; long runs may require thicker wires to minimize voltage drop. White: 14 AWG wire (2.08 mm 2) for 15-amp circuits Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits