enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Flex temp - Wikipedia

    en.wikipedia.org/wiki/Flex_temp

    This false ambient temperature is the flex temp. [3] The flex temp is entered into the flight management system (FMS) — effectively telling the engine control system to assume the specified air temperature instead of the actual outside air temperature in calculating the maximum thrust available under current conditions. Setting the throttle ...

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  4. Volume correction factor - Wikipedia

    en.wikipedia.org/wiki/Volume_Correction_Factor

    In thermodynamics, the Volume Correction Factor (VCF), also known as Correction for the effect of Temperature on Liquid (CTL), is a standardized computed factor used to correct for the thermal expansion of fluids, primarily, liquid hydrocarbons at various temperatures and densities. [1]

  5. Total air temperature - Wikipedia

    en.wikipedia.org/wiki/Total_air_temperature

    Total air temperature is an essential input to an air data computer in order to enable the computation of static air temperature and hence true airspeed. The relationship between static and total air temperatures is given by: T t o t a l T s = 1 + γ − 1 2 M a 2 {\displaystyle {\frac {T_{\mathrm {total} }}{T_{s}}}={1+{\frac {\gamma -1}{2}}M ...

  6. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an improvement over: It is an improvement over:

  7. Logarithmic mean temperature difference - Wikipedia

    en.wikipedia.org/wiki/Logarithmic_mean...

    In thermal engineering, the logarithmic mean temperature difference (LMTD) is used to determine the temperature driving force for heat transfer in flow systems, most notably in heat exchangers. The LMTD is a logarithmic average of the temperature difference between the hot and cold feeds at each end of the double pipe exchanger.

  8. Operative temperature - Wikipedia

    en.wikipedia.org/wiki/Operative_temperature

    Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...

  9. Normal shock tables - Wikipedia

    en.wikipedia.org/wiki/Normal_shock_tables

    In aerodynamics, the normal shock tables are a series of tabulated data listing the various properties before and after the occurrence of a normal shock wave. [1] With a given upstream Mach number, the post-shock Mach number can be calculated along with the pressure, density, temperature, and stagnation pressure ratios.