The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .
One example of standard conditions for the calculation of SCCM is = 0 °C (273.15 K) [1] and = 1.01 bar (14.72 psia) and a unity compressibility factor = 1 (i.e., an ideal gas is used for the definition of SCCM). [2] This example is for the semi-conductor-manufacturing industry.
The AGA 7 calculation itself is a simple ratio and is, in essence, a density correction approach to translating the volume or rate of gas at flowing conditions to a volume or rate at base conditions. Orifice meters are a very commonly used type of meter, and because of their widespread use, the characteristics of gas flow through an orifice ...
GVF – Gas volume fraction is the ratio of the gas volumetric flow rate to the total volumetric flow rate. LVF – Liquid volume fraction is the ratio of the liquid volumetric flow rate to the total volumetric flow rate. Hold up is the cross sectional area occupied by the liquid in the pipe carrying the wet gas flow.
Orifice plate includes derivation of non-choked gas flow equation. de Laval nozzles are venturi tubes that produce supersonic gas velocities as the tube and the gas are first constricted and then the tube and gas are expanded beyond the choke plane. Rocket engine nozzles discusses how to calculate the exit velocity from nozzles used in rocket ...
Darcy–Weisbach equation calculator; Pipe pressure drop calculator Archived 2019-07-13 at the Wayback Machine for single phase flows. Pipe pressure drop calculator for two phase flows. Archived 2019-07-13 at the Wayback Machine; Open source pipe pressure drop calculator. Web application with pressure drop calculations for pipes and ducts
The ideal gas equation can be rearranged to give an expression for the molar volume of an ideal gas: = = Hence, for a given temperature and pressure, the molar volume is the same for all ideal gases and is based on the gas constant: R = 8.314 462 618 153 24 m 3 ⋅Pa⋅K −1 ⋅mol −1, or about 8.205 736 608 095 96 × 10 −5 m 3 ⋅atm⋅K ...
For pipe flows a so-called transit time method is applied where a radiotracer is injected as a pulse into the measured flow. The transit time is defined with the help of radiation detectors placed on the outside of the pipe. The volume flow is obtained by multiplying the measured average fluid flow velocity by the inner pipe cross-section.