Poorly insulated walls: 2 W/(m 2 ⋅K) Well-insulated floors: 0.2 W/(m 2 ⋅K) Poorly insulated floors: 1.0 W/(m 2 ⋅K) In practice the thermal transmittance is strongly affected by the quality of workmanship and if insulation is fitted poorly, the thermal transmittance can be considerably higher than if insulation is fitted well [3]
Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...
The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.
Quadruple glazed office building in Oslo, Norway, U-value 0.29 W/m 2 K, R-value 20. The insulation effectiveness can be expressed as an R-value or RSI value. The higher the value, the greater is its resistance to heat transfer. A standard IGU consisting of clear uncoated panes of glass (or lights) with air in the cavity between the lights ...
The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]
Dynamic insulation works best with a good thickness of insulation so taking 200 mm of cellulose insulation (k = 0.04 W/m °C) the dynamic U value for an air flow of 0.31 mm/s is calculated using equation above to be 0.066 W/m 2 °C. If a lower dynamic U-value is required then a material with lower air permeability than fibreboard would need to ...