  1. Results from the WOW.Com Content Network
  2. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units.

  3. Boost converter - Wikipedia

    en.wikipedia.org/wiki/Boost_converter

    A boost converter or step-up converter is a DC-to-DC converter that increases voltage, while decreasing current, from its input to its output . It is a class of switched-mode power supply (SMPS) containing at least two semiconductors, a diode and a transistor , and at least one energy storage element: a capacitor , inductor , or the two in ...

  4. Royer oscillator - Wikipedia

    en.wikipedia.org/wiki/Royer_oscillator

    A Royer oscillator is an electronic relaxation oscillator that employs a saturable-core transformer in the main power path. It was invented and patented in April 1954 by Richard L. Bright & George H. Royer, who are listed as co-inventors on the patent. [1]

  5. Electrical transformers could be a giant bottleneck waiting ...

    www.aol.com/finance/electrical-transformers...

    In order to effectively transmit power across hundreds of miles, transformers are needed to “step up” voltage to a higher level on the transmitting end, says Boucher. But that high-voltage ...

  6. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°. According to the IEC60076-1 standard, the notation is HV-LV in sequence. For example, a step-up transformer with a delta-connected primary and a wye-connected secondary is still labeled as 'Yd1'. The 1 indicates the LV winding lags the HV by 30 degrees. [1]

  7. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant. Isolated phase bus during installation at the Bui Dam Ghana ...

  8. Korndörfer autotransformer starter - Wikipedia

    en.wikipedia.org/wiki/Korndörfer_Autotransformer...

    A further transient problem is that with a single coil construction and a star switch, the autotransformer acts as a step-up transformer during the <5 microsecond period at contact separation of the Star point switch. With the motor connected to the 80% voltage tap there will be an escalation of the transient by 5:1 ratio.

  9. Tesla coil - Wikipedia

    en.wikipedia.org/wiki/Tesla_coil

    [26] [27] [28] They consist of a two coil air-core step-up transformer similar to the Tesla transformer, with the secondary connected to a third coil not magnetically coupled to the others, called the "extra" or "resonator" coil, which is series-fed and resonates with its own capacitance. The output is taken from the free end of this coil.