Search results
Results from the WOW.Com Content Network
Circuit-breakers can be placed at portions of a circuit in series to the path of current it will affect. If more current than expected goes through the circuit-breaker, the circuit breaker "opens" the circuit and stops all current. A fuse is a common type of circuit breaker that involves direct effect of Joule-overheating.
A resistor removed from a high voltage tube circuit shows damage from voltaic arcing on the resistive metal oxide layer. Resistors can fail open or short, alongside their value changing under environmental conditions and outside performance limits. Examples of resistor failures include: Manufacturing defects causing intermittent problems.
In a "ground fault" or "earth fault", current flows into the earth. The prospective short-circuit current of a predictable fault can be calculated for most situations. In power systems, protective devices can detect fault conditions and operate circuit breakers and other devices to limit the loss of service due to a failure.
A simple example of an effectively random cause in a physical system is a borderline electrical connection in the wiring or a component of a circuit, where (cause 1, the cause that must be identified and rectified) two conductors may touch subject to (cause 2, which need not be identified) a minor change in temperature, vibration, orientation ...
An unregulated DC supply will produce a lower output voltage. The output voltage ripple will decrease in line with the usually reduced load current. In a cathode-ray tube television, the reduced output voltage will make the screen image smaller, dimmer and fuzzier.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
A ground conductor only carries significant current if there is a circuit fault that would otherwise energize exposed conductive parts and present a shock hazard. In that case, circuit protection devices may detect a fault to a grounded metal enclosure and automatically de-energize the circuit, or may provide a warning of a ground fault.
To prevent electric power distribution network damage, each station along the network is protected with circuit breakers or fuse cutouts which turn off power in the event of a short circuit. These protection solutions present a major problem when restoring power immediately following transient events, because repair crews need to manually reset ...