enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Aluminium-conductor steel-reinforced cable - Wikipedia

    en.wikipedia.org/wiki/Aluminium-conductor_steel...

    An ACSR conductor can in part be denoted by its stranding, for example, an ACSR conductor with 72 aluminium strands with a core of 7 steel strands will be called 72/7 ACSR conductor. [ 3 ] [ 4 ] [ 5 ] Cables generally range from #6 AWG ("6/1" – six outer aluminum conductors and one steel reinforcing conductor) to 2167 kcmil ("72/7 ...

  3. Aerial bundled cable - Wikipedia

    en.wikipedia.org/wiki/Aerial_bundled_cable

    In the Dandenong Ranges area Victoria 2014. Medium voltage (11-22 kV) ABC is being replaced with underground cable due to high failure rates of HV ABC, with life expectancy of just 10 years, when original life was expected to be approx 30 years. Due to degraded cable, cost of repairs & maintenance and bushfire risk.

  4. Overhead power line - Wikipedia

    en.wikipedia.org/wiki/Overhead_power_line

    The carbon core conductor's reduced thermal sag allows it to carry up to twice the current ("ampacity") compared to all-aluminum conductor (AAC) or ACSR. The power lines and their surroundings must be maintained by linemen , sometimes assisted by helicopters with pressure washers or circular saws which may work three times faster.

  5. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    Several kinds of ratings may be made available, including: real-time, indicating ampacity immediately available, without time limits should conditions remain identical; emergency ratings for a limited duration; and same-day and day-ahead forecasts. DLR computations deal with "near real-time" data, updated about every five minutes.

  6. Circuit integrity - Wikipedia

    en.wikipedia.org/wiki/Circuit_integrity

    Circuit integrity fireproofing of cable trays using calcium silicate board system Circuit integrity fireproofing of cable trays Fire-resistant cables MI cables fastened into junction box that has not been fireproofed. Circuit integrity describes the extent of a fire's effect on an electrical circuit's operation. It is a form of fire-resistance ...

  7. ACCC conductor - Wikipedia

    en.wikipedia.org/wiki/ACCC_conductor

    Its light weight and softness result in roughly 30% greater conductivity than an equivalent ACSR conductor, allowing 14% more current to be carried at equal temperature. For example, 1.107 in (28.1 mm) diameter ACCC "Drake" conductor at 75 °C has an AC resistance of 106 mΩ/mile, [ 7 ] while equivalent ACSR conductor has an AC resistance of ...

  8. Electrical conductor - Wikipedia

    en.wikipedia.org/wiki/Electrical_conductor

    The ampacity of a conductor, that is, the amount of current it can carry, is related to its electrical resistance: a lower-resistance conductor can carry a larger value of current. The resistance, in turn, is determined by the material the conductor is made from (as described above) and the conductor's size.

  9. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    The equation in section 310-15(C) of the National Electrical Code, called the Neher–McGrath equation (NM), may be used to estimate the effective ampacity of a cable: [3] = (+) (+), In the equation, T c {\textstyle T_{c}} is normally the limiting conductor temperature derived from the insulation or tensile strength limitations.