The Revised Fire Code of the Philippines of 2008, officially codified as Republic Act No. 9514, is a consolidation of Senate Bill No. 2553 and House Bill No. 4115, enacted and passed the Senate and the House of Representatives on October 6, 2008 and October 8, 2008, respectively.
Bureau of Fire Protection National headquarters along Senator Miriam P. Defensor-Santiago Avenue (formerly Agham Road) in Quezon City. The BFP was formed from the units of the Integrated National Police's Office of Fire Protection Service on January 29, 1991 through Republic Act No. 6975, which created the present Interior Department and placed the provision of fire services under its control.
For some high challenge occupancies, [4] the code requirements for an occupancy separation are more stringent than for other fire barriers, even with an identical fire resistance rating. In this case, an occupancy separation with a two-hour fire-resistance rating may not be able to "de-rate" its closures, such fire doors and firestops.
Many buildings may have multiple occupancies. These are referred to as "mixed occupancies" and the different parts will be required to meet the codes for those specific areas. An example of this is a shopping mall with underground parking. The shopping area itself is Group M (mercantile), while the parking area would qualify as Group S (storage).
A building under construction, showing the structurally independent cinderblock firewalls subdividing the building Building 4 of the Waynesboro Outlet Village, showing a concrete firewall running through the building Concrete firewalls still standing on Building 7 of the former Waynesboro Outlet Village, following a firefighter training exercise which intentionally burned the building
Canada de-rates closures, where, for instance a 2-hour closure is acceptable for use in a 3-hour fire separation, so long as the fire separation is not an occupancy separation or firewall. The lowered rating is then referred to as a fire protection rating, both for firestops, unless they contain plastic pipes and regular closures. Firestops
Sprinkler branch pipe through-penetration with plastic sleeve - missing firestop in concrete fire separation. The space between the sleeve and the pipe is the annulus or annular space. The annulus, or annular space, is the space between a penetrant and anything that surrounds it, such as the sides of an opening or a sleeve, as the case may be. [1]
The publication Life Safety Code, known as NFPA 101, is a consensus standard widely adopted in the United States. [according to whom?] It is administered, trademarked, copyrighted, and published by the National Fire Protection Association and, like many NFPA documents, is systematically revised on a three-year cycle.