Most ozone monitors utilized in regulatory applications use ultraviolet absorption to accurately quantify ozone levels. An ozone monitor of this type operates by pulling an air sample from the atmosphere into the machine with an air pump. [3] During one cycle, the ozone monitor will take one air sample through the air inlet, and scrub the ozone ...
A typical calibration schedule for a portable gas detector is a daily "bump test" accompanied by a monthly calibration. [17] Almost every portable gas detector requires a specific calibration gas In the US, the Occupational Safety and Health Administration (OSHA) may set minimum standards for periodic recalibration. [citation needed]
The ozone monitoring instrument (OMI) [1] is a nadir-viewing visual and ultraviolet spectrometer aboard the NASA Aura spacecraft, which is part of the satellite constellation A-Train. In this group of satellites Aura flies in formation about 15 minutes behind Aqua satellite , both of which orbit the Earth in a polar Sun-synchronous pattern, and ...
In a photoionization detector, high-energy photons, typically in the vacuum ultraviolet (VUV) range, break molecules into positively charged ions. [2] As compounds enter the detector they are bombarded by high-energy UV photons and are ionized when they absorb the UV light, resulting in ejection of electrons and the formation of positively charged ions.
Unlike low-cost monitors, which are carried from place to place, static monitors continuously sample and measure the air quality in a particular, urban location. Public places such as busy railroad stations sometimes have active air quality monitors permanently fixed alongside platforms to measure levels of nitrogen dioxide and other pollutants ...
Ventilation with outdoor air containing elevated ozone concentrations may complicate remediation attempts. [69] The WHO standard for ozone concentration is 60 μg/m 3 for long-term exposure and 100 μg/m 3 as the maximum average over an 8-hour period. [29] The EPA standard for ozone concentration is 0.07 ppm average over an 8-hour period. [70]