enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Switchyard reactor - Wikipedia

    en.wikipedia.org/wiki/Switchyard_reactor

    In large systems with many generators connected in parallel, it may be necessary to use a series reactor to prevent excessively large current flow during a short circuit; this protects transmission line conductors and switching apparatus from damage due to high currents and forces produced during a short circuit. A shunt reactor is connected in ...

  3. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    A shunt in the ungrounded conductor must be insulated for the full circuit voltage to ground; the measuring instrument must be inherently isolated from ground or must include a resistive voltage divider or an isolation amplifier between the relatively high common-mode voltage and lower voltages inside the instrument. A shunt in the grounded ...

  4. Variable shunt reactor - Wikipedia

    en.wikipedia.org/wiki/Variable_shunt_reactor

    A traditional shunt reactor has a fixed rating and is either connected to the power line all the time or switched in and out depending on the load. Recently [1] variable shunt reactors (VSRs) have been developed and introduced on the market. The rating of a VSR can be changed in steps: the maximum regulation range depends on the capability of ...

  5. Magnetically controlled shunt reactor - Wikipedia

    en.wikipedia.org/wiki/Magnetically_Controlled...

    A magnetically-controlled shunt reactor (MCSR, CSR) represents electrotechnical equipment purposed for compensation of reactive power and stabilization of voltage level in high voltage (HV) electric networks rated for voltage classes 36 – 750 kV. MCSR is shunt-type static device with smooth regulation by means of inductive reactance.

  6. Static VAR compensator - Wikipedia

    en.wikipedia.org/wiki/Static_VAR_compensator

    Typically, an SVC comprises one or more banks of fixed or switched shunt capacitors or reactors, of which at least one bank is switched by thyristors. Elements which may be used to make an SVC typically include: Thyristor-controlled reactor (TCR), where the reactor may be air- or iron-cored; Thyristor-switched capacitor (TSC) Harmonic filter(s)

  7. Flexible AC transmission system - Wikipedia

    en.wikipedia.org/wiki/Flexible_AC_transmission...

    The goal shunt compensation is to connect a device in parallel with the system that will improve voltage and enable larger power flow. This is traditionally done using shunt capacitors and inductors (reactors), [13] much like Power Factor Correction. The most common shunt compensation device is the Static VAR Compensator (SVC). [14]

  8. Static synchronous compensator - Wikipedia

    en.wikipedia.org/wiki/Static_synchronous_compensator

    Fixed, shunt capacitor and reactor banks filled this need by being deployed where needed. In particular, shunt capacitors switched by circuit breakers provided an effective means to managing varying reactive power requirements due to changing loads. [3] However, this was not without limitations.

  9. High-voltage direct current - Wikipedia

    en.wikipedia.org/wiki/High-voltage_direct_current

    The shunt capacitors are almost always provided with tuning reactors and, where necessary, damping resistors so that they can perform a dual role as harmonic filters. VSCs, on the other hand, can either produce or consume reactive power on demand, with the result that usually no separate shunt capacitors are needed (other than those required ...